Output trends, characteristics, and measurements of three megavoltage radiotherapy linear accelerators
Open Access
- 8 July 2014
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 15 (4) , 137-151
Abstract
The purpose of this study is to characterize and understand the long‐term behavior of the output from megavoltage radiotherapy linear accelerators. Output trends of nine beams from three linear accelerators over a period of more than three years are reported and analyzed. Output, taken during daily warm‐up, forms the basis of this study. The output is measured using devices having ion chambers. These are not calibrated by accredited dosimetry laboratory, but are baseline‐compared against monthly output which is measured using calibrated ion chambers. We consider the output from the daily check devices as it is, and sometimes normalized it by the actual output measured during the monthly calibration of the linacs. The data show noisy quasi‐periodic behavior. The output variation, if normalized by monthly measured “real’ output, is bounded between ± 3%. Beams of different energies from the same linac are correlated with a correlation coefficient as high as 0.97, for one particular linac, and as low as 0.44 for another. These maximum and minimum correlations drop to 0.78 and 0.25 when daily output is normalized by the monthly measurements. These results suggest that the origin of these correlations is both the linacs and the daily output check devices. Beams from different linacs, independent of their energies, have lower correlation coefficient, with a maximum of about 0.50 and a minimum of almost zero. The maximum correlation drops to almost zero if the output is normalized by the monthly measured output. Some scatter plots of pairs of beam output from the same linac show band‐like structures. These structures are blurred when the output is normalized by the monthly calibrated output. Fourier decomposition of the quasi‐periodic output is consistent with a 1/f power law. The output variation appears to come from a distorted normal distribution with a mean of slightly greater than unity. The quasi‐periodic behavior is manifested in the seasonally averaged output, showing annual variability with negative variations in the winter and positive in the summer. This trend is weakened when the daily output is normalized by the monthly calibrated output, indicating that the variation of the periodic component may be intrinsic to both the linacs and the daily measurement devices. Actual linac output was measured monthly. It needs to be adjusted once every three to six months for our tolerance and action levels. If these adjustments are artificially removed, then there is an increase in output of about 2%–4% per year.PACS numbers: 87.56bd, 87.56Fc, 87.55QrKeywords
Funding Information
- National Cancer Institute (P30 CA006927)
This publication has 14 references indexed in Scilit:
- Retrospective analysis of linear accelerator output constancy checks using process control techniquesJournal of Applied Clinical Medical Physics, 2013
- Analysis of output trends from Varian 2100C/D and 600C/D acceleratorsPhysics in Medicine & Biology, 2010
- Task Group 142 report: Quality assurance of medical acceleratorsa)Medical Physics, 2009
- The influence of output measurement time interval and tolerance on treatment dose deviation in photon external beam radiotherapyPhysics in Medicine & Biology, 2006
- Linear accelerator output variabilityAustralasian Physics & Engineering Sciences in Medicine, 2004
- Complex behavior in switching power convertersProceedings of the IEEE, 2002
- Nonlinear Phenomena in Power Electronics2001
- AAPM's TG‐51 protocol for clinical reference dosimetry of high‐energy photon and electron beamsMedical Physics, 1999
- Dynamic Pattern Formation Leads toNoise in Neural PopulationsPhysical Review Letters, 1995
- Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40Medical Physics, 1994