Dispersive multi-walled carbon nanotubes extraction of benzenesulfonamides, benzotriazoles, and benzothiazoles from environmental waters followed by microwave desorption and HPLC-HESI-MS/MS
Authors:
- 25 October 2017
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 409 (28) , 6709-6718
Abstract
This work shows a novel analytical method for the simultaneous extraction of environmental emerging contaminants as benzenesulfonamides (BSAs), benzotriazoles (BTRs), and benzothiazoles (BTs) from water samples. Pristine multi-walled carbon nanotubes (MWCNTs), not yet tested for such analytes, are here employed as the sorbent phase for dispersive solid-phase extraction (d-SPE) followed by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC-HESI-MS/MS). Quantitative sorption is gained by treating 50 mL sample with 100 mg MWCNTs (2 g L−1) in 10 min contact, both in tap and raw river water. After sorption, the analytes are quantitatively desorbed by microwaves (20 min, 160 °C, 250 W) by using 5 mL methanol-ethylacetate-acetic acid (10:70:20, v/v), according to the indications obtained by a chemometric study. The extract is reduced to small volume before analysis, thus reaching overall enrichment factors up to 400. Recovery of the entire procedure, evaluated on tap and surface water samples spiked with 0.1/0.5–50 μg L−1 of each analyte, was in the range 70–116%, with excellent inter-day precision (RSD < 7%). Selectivity and firm analyte identification were assured by MRM detection, and suitable sensitivity was obtained for determination of these pollutants in actual matrices (experimental MDLs 30–170 ng L−1). The proposed analytical method was applied to the analysis of surface water samples, containing concentrations of these contaminants ranging from 100 ng L−1 to 2 μg L−1. Pristine MWCNTs proved to be a valid alternative to other commercial sorbents, both in terms of cost and sorption capacity.Keywords
This publication has 46 references indexed in Scilit:
- Efficient tandem solid-phase extraction and liquid chromatography-triple quadrupole mass spectrometry method to determine polar benzotriazole, benzothiazole and benzenesulfonamide contaminants in environmental water samplesJournal of Chromatography A, 2013
- Adsorption of Cu(II) on Oxidized Multi-Walled Carbon Nanotubes in the Presence of Hydroxylated and Carboxylated FullerenesPLOS ONE, 2013
- Estrogenic potential of benzotriazole on marine medaka (Oryzias melastigma)Ecotoxicology and Environmental Safety, 2012
- Investigation of the fate of sulfonamides downgradient of a decommissioned sewage farm near Berlin, GermanyJournal of Contaminant Hydrology, 2009
- Determination of polar 1H-benzotriazoles and benzothiazoles in water by solid-phase extraction and liquid chromatography LTQ FT Orbitrap mass spectrometryInternational Journal of Mass Spectrometry, 2009
- Bladder cancer risks in workers manufacturing chemicals for the rubber industryOccupational Medicine, 2008
- Determination of Benzotriazole Corrosion Inhibitors from Aqueous Environmental Samples by Liquid Chromatography-Electrospray Ionization-Tandem Mass SpectrometryAnalytical Chemistry, 2005
- In vitro and in vivo estrogenicity of UV screens.Environmental Health Perspectives, 2001
- Detection of Aircraft Deicing/Antiicing Fluid Additives in a Perched Water Monitoring Well at an International AirportEnvironmental Science & Technology, 1998
- Toxicity of aircraft de-icer and anti-icer solutions to aquatic organismsEnvironmental Toxicology and Chemistry, 1995