Dose assessment from an online kilovoltage imaging system in radiation therapy
Authors:
- Ernest K OseiEOErnest K Osei
- Bryan SchalyBSBryan Schaly
- Andre FleckAFAndre Fleck
- Paule CharlandPCPaule Charland
- Rob BarnettRBRob Barnett
- 18 February 2009
- journal article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 29 (1) , 37-50
Abstract
We have investigated the dosimetric properties of a commercial kilovoltage cone beam computerised tomography (kV-CBCT) system. The kV-CBCT doses were measured in 16 and 32 cm diameter standard cylindrical Perspex computerised tomography (CT) and Rando anthropomorphic phantoms using 125 kVp and 1.0-2.0 mA s per projection. We also measured skin doses using thermoluminescence dosimeters placed on the skin surfaces of prostate cancer patients undergoing kV-kV image matching for daily set-up. The skin doses from kV-kV image matching of prostate cancer patients on the anterior and lateral skin surfaces ranged from 0.03 +/- 0.01 to 0.64 +/- 0.01 cGy depending on the beam filtration and technique factors employed. The mean doses on the Rando phantom ranged from 3.0 +/- 0.1 to 5.1 +/- 0.3 cGy for full-fan scans and from 3.8 +/- 0.1 to 6.6 +/- 0.2 cGy for half-fan scans using 125 kVp and 2 mA s per projection. The isocentre cone beam dose index (CBDI) in the 16 and 32 cm Perspex phantoms is 4.65 and 1.81 cGy, respectively (using a 0.6 cm(3) Capintec PR06C Farmer chamber) for full-fan scans, and the corresponding normalised CBDIs are 0.72 and 0.28 cGy/100 mA s, respectively. The mean weighted CBDIs are 4.93 and 2.14 cGy, and the normalised weighted CBDIs are 0.76 and 0.33 cGy/100 mA s for the 16 and 32 cm phantoms, respectively (full-fan scans). The normalised weighted CBDI for the half-fan scan is 0.41 cGy/100 mA s for the 32 cm diameter phantom. All measurements of the CBDI using the 0.6 cm(3) Farmer chamber are within 2-5% of measurements taken with the 100 mm CT chamber. The CBDI technique and definitions can be used to benchmark CBCT systems and to provide estimates of imaging doses to patients undergoing on-board imager (OBI)/CBCT image guided radiation therapy.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of daily online set-up errors and organ displacement uncertainty during conformal radiation treatment of the prostateBritish Journal of Radiology, 2009
- Imaging doses from the Elekta Synergy X-ray cone beam CT systemBritish Journal of Radiology, 2007
- Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancerPhysics in Medicine & Biology, 2007
- Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapyPhysics in Medicine & Biology, 2007
- Patient dose and image quality from mega‐voltage cone beam computed tomography imagingMedical Physics, 2007
- Dose and image quality for a cone‐beam C‐arm CT systemMedical Physics, 2006
- Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapyMedical Physics, 2006
- Evaluation of dose efficiency index compared to receiver operating characteristics for assessing CT low-contrast performance2004
- A comparison of daily CT localization to a daily ultrasound-based system in prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1999
- Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladderInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991