Tetrahedron beam computed tomography (TBCT): a new design of volumetric CT system
Authors:
- Tiezhi ZhangTZTiezhi Zhang
- Derek SchulzeDSDerek Schulze
- Xiaochao XuXXXiaochao Xu
- Joshua KimJKJoshua Kim
- 8 May 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (11) , 3365-3378
Abstract
Volumetric CT imaging systems usually comprise a point x-ray source and a 2D detector. Flat panel imager (FPI)-based cone beam CT (CBCT) has become an important online imaging modality for image-guided radiotherapy and intervention. However, due to excessive scatter photons and inferior detector performance, the image quality of current CBCT is significantly inferior to diagnostic fan-beam CT. We propose a novel tetrahedron beam computed tomography (TBCT) imaging system which consists of a linear scan x-ray source and a linear x-ray detector array. The linear x-ray tube and detector array are aligned perpendicular and parallel to the rotation plane, respectively. The x-ray beams are narrowly collimated into fan beams and focused on the linear detector array. The linear detector and linear x-ray source form a 'tetrahedron' volume instead of a 'cone' volume. TBCT is similar to CBCT in image reconstruction geometry; however, its image quality will be significantly superior to that of CBCT due to its scatter rejection mechanism and the use of high-performance discrete x-ray detectors. In this paper, we describe the design of the TBCT system for image-guided radiotherapy and some results of preliminary studies.Keywords
This publication has 22 references indexed in Scilit:
- Magnitude and effects of x-ray scatter in a 256-slice CT scannerMedical Physics, 2006
- A prototype table-top inverse-geometry volumetric CT systemMedical Physics, 2006
- Scatter rejection in multislit digital mammographyMedical Physics, 2006
- TU-D-I-611-08: Cone Beam X-Ray Scatter Removal Via Image Frequency Modulation and FilteringMedical Physics, 2005
- Grid and Slot Scan Scatter Reduction in Mammography: Comparison by Using Monte Carlo TechniquesRadiology, 2002
- Effect of scattered radiation on image noise in cone beam CTMedical Physics, 2001
- Scattered radiation in scanning slot mammographyMedical Physics, 1998
- X‐ray scatter in megavoltage transmission radiography: Physical characteristics and influence on image qualityMedical Physics, 1994
- An analytical model of the scattered radiation distribution in diagnostic radiologyMedical Physics, 1988
- Monte Carlo simulation of the scattered radiation distribution in diagnostic radiologyMedical Physics, 1988