Loop‐Mediated Isothermal Amplification for Detection of Nucleic Acids
Authors:
Open Access
- 6 January 2014
- journal article
- unit
- Published by Wiley in Current Protocols in Molecular Biology
- Vol. 105 (1) , 15.14.1-15.14.14
Abstract
Sequence‐specific isothermal nucleic acid amplification techniques are ideally suited for use in molecular diagnostic applications because they do not require thermal cycling equipment and the reactions are typically fast. One of the most widely cited isothermal techniques is termed loop‐mediated isothermal amplification (LAMP). This protocol allows amplification times as fast as 5 to 10 min. Furthermore, various methodologies to detect amplification have been applied to LAMP to increase its utility for the point‐of‐care market. Basic LAMP protocols are provided herein for detection of specific DNA and RNA targets, along with a method to perform multiplex LAMP reactions, permitting even greater flexibility from this powerful technique. Curr. Protoc. Mol. Biol. 105:15.14.1‐15.14.14. © 2014 by John Wiley & Sons, Inc.Keywords
This publication has 18 references indexed in Scilit:
- Detection of capripoxvirus DNA using a novel loop-mediated isothermal amplification assayBMC Veterinary Research, 2013
- Multiplex Loop-Mediated Isothermal Amplification Detection by Sequence-Based Barcodes Coupled with Nicking Endonuclease-Mediated PyrosequencingAnalytical Chemistry, 2012
- Point-of-care nucleic acid testing for infectious diseasesTrends in Biotechnology, 2011
- Development of a multiplex loop-mediated isothermal amplification (mLAMP) method for the simultaneous detection of white spot syndrome virus and infectious hypodermal and hematopoietic necrosis virus in penaeid shrimpAquaculture, 2011
- Novel Bioluminescent Quantitative Detection of Nucleic Acid Amplification in Real-TimePLOS ONE, 2010
- A single fluorescence-based LAMP reaction for identifying multiple parasites in mosquitoesExperimental Parasitology, 2010
- Colorimetric Detection of Loop-Mediated Isothermal Amplification Reaction by Using Hydroxy Naphthol BlueBioTechniques, 2009
- Tolerance of loop-mediated isothermal amplification to a culture medium and biological substancesJournal of Biochemical and Biophysical Methods, 2007
- Comparison of SYTO9 and SYBR Green I for real-time polymerase chain reaction and investigation of the effect of dye concentration on amplification and DNA melting curve analysisAnalytical Biochemistry, 2005
- Real-time turbidimetry of LAMP reaction for quantifying template DNAJournal of Biochemical and Biophysical Methods, 2004