International Society for the Advancement of Cytometry cell sorter biosafety standards
Open Access
- 13 March 2014
- journal article
- research article
- Published by Wiley in Cytometry Part A
- Vol. 85 (5) , 434-453
Abstract
Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99–117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414–437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment. Published © 2013 Wiley Periodicals Inc.†Keywords
This publication has 33 references indexed in Scilit:
- Characterization of aerosols produced by cell sorters and evaluation of containmentCytometry Part A, 2011
- Influence of particle size on regional lung deposition – What evidence is there?International Journal of Pharmaceutics, 2011
- Laboratory‐Acquired InfectionsClinical Infectious Diseases, 2009
- Review of Aerosol Transmission of Influenza A VirusEmerging Infectious Diseases, 2006
- Ultra high‐speed sortingCytometry Part A, 2005
- Biosafety concerns for shared flow cytometry core facilitiesCytometry Part A, 2003
- Measuring containment of viable infectious cell sorting in high‐velocity cell sortersCytometry Part A, 2003
- Method for Visualizing Aerosol Contamination in Flow SortersCurrent Protocols in Cytometry, 2002
- Effects of whole blood lysis and fixation on the infectivity of human T-lymphotropic virus type 1 (HTLV-I)Cytometry, 1994