Midterm Results of Retrograde In Situ Needle Fenestration During Thoracic Endovascular Aortic Repair of Aortic Arch Pathologies
Authors:
- 1 September 2020
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 28 (1) , 36-43
Abstract
Purpose: To evaluate the safety and feasibility of the in situ needle fenestration (ISNF) technique for reconstruction of the left subclavian artery (LSA) during thoracic endovascular aortic repair (TEVAR) of complicated aortic arch pathologies. Materials and Methods: A retrospective review was conducted from January 2014 to December 2019 of 50 patients (mean age 60.2±11.1; 45 men) who underwent ISNF to revascularize the LSA during TEVAR. Twenty-one of the patients also required revascularization of the left common carotid artery (LCCA; n=19) and innominate artery (IA; n=2) using physician-modified in vitro fenestration. Overall, 73 supra-aortic branches were targeted for revascularization. Results: ISNF was successful in 48 patients (96%); one LSA could not be stented and a tortuous LSA prevented the needle from fenestrating the graft. No perioperative major adverse event occurred. There were no type I and 4 type III endoleaks (8%), 3 of which occurred among the first 20 cases. Types II and IV endoleaks were found in 3 (6%) and 6 (12%) cases, respectively; all disappeared during a median follow-up of 15 months (range 3–66). One death (2%) occurred within 12 months due to cerebral hemorrhage. Two patients (4%) required open reinterventions at 6 and 62 months. Conclusion: ISNF for revascularization of the LSA during TEVAR seems to be feasible with acceptable midterm outcomes. The learning curve and evolving patient selection criteria affected technical success, complications, and the need for reinterventions. Long-term durability requires further evaluation.Keywords
Funding Information
- Grant of CAMS Initiative for Innovative Medicine, China (2016-I2M-1-016)
- National Natural Science Foundation of China (81870345)
- Beijing Science and Technology Project (D171100002917004)
This publication has 20 references indexed in Scilit:
- Fenestrated Thoracic Endovascular Aortic Repair Using Physician Modified Stent Grafts for Acute Type B Aortic Dissection with Unfavourable Landing ZoneEuropean Journal of Vascular and Endovascular Surgery, 2018
- First experience with the double chimney technique in the treatment of aortic arch diseasesJournal of Vascular Surgery, 2017
- Physician-Modified Thoracic Stent-Grafts for the Treatment of Aortic Arch LesionsJournal of Endovascular Therapy, 2017
- Long-term durability of aortic arch in situ stent graft fenestration requiring lifelong surveillanceJournal of Vascular Surgery, 2016
- Laser Generated In situ Fenestrations in Dacron Stent GraftsEuropean Journal of Vascular and Endovascular Surgery, 2016
- Radiofrequency In Situ Fenestration for Aortic Arch Vessels During Thoracic Endovascular RepairJournal of Endovascular Therapy, 2015
- Twelve-year results of fenestrated endografts for juxtarenal and group IV thoracoabdominal aneurysmsJournal of Vascular Surgery, 2015
- Endovascular Repair of Type B Aortic DissectionCirculation: Cardiovascular Interventions, 2013
- Early Results of Left Carotid Chimney Technique in Endovascular Repair of Acute Non-A–Non-B Aortic DissectionsJournal of Endovascular Therapy, 2011
- In Situ Stent-Graft Fenestration to Preserve the Left Subclavian ArteryJournal of Endovascular Therapy, 2004