A New Method to Minimize the Standard Deviation and Root Mean Square of the Prediction Error of Single-Optimized IOL Power Formulas
Authors:
Open Access
- 3 June 2024
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 13 (6) , 2
Abstract
Purpose: The purpose of this study was to develop a simplified method to approximate constants minimizing the standard deviation (SD) and the root mean square (RMS) of the prediction error in single-optimized intraocular lens (IOL) power calculation formulas. Methods: The study introduces analytical formulas to determine the optimal constant value for minimizing SD and RMS in single-optimized IOL power calculation formulas. These formulas were tested against various datasets containing biometric measurements from cataractous populations and included 10,330 eyes and 4 different IOL models. The study evaluated the effectiveness of the proposed method by comparing the outcomes with those obtained using traditional reference methods. Results: In optimizing IOL constants, minor differences between reference and estimated A-constants were found, with the maximum deviation at −0.086 (SD, SRK/T, and Vivinex) and −0.003 (RMS, PEARL DGS, and Vivinex). The largest discrepancy for third-generation formulas was −0.027 mm (SD, Haigis, and Vivinex) and 0.002 mm (RMS, Hoffer Q, and PCB00/SN60WF). Maximum RMS differences were −0.021 and +0.021, both involving Hoffer Q. Post-minimization, the largest mean prediction error was 0.726 diopters (D; SD) and 0.043 D (RMS), with the highest SD and RMS after adjustments at 0.529 D and 0.875 D, respectively, indicating effective minimization strategies. Conclusions: The study simplifies the process of minimizing SD and RMS in single-optimized IOL power predictions, offering a valuable tool for clinicians. However, it also underscores the complexity of achieving balanced optimization and suggests the need for further research in this area. Translational Relevance: The study presents a novel, clinically practical approach for optimizing IOL power calculations.Keywords
This publication has 24 references indexed in Scilit:
- A Simplified Method to Minimize Systematic Bias of Single-Optimized Intraocular Lens Power Calculation FormulasAmerican Journal of Ophthalmology, 2023
- The PEARL-DGS Formula: The Development of an Open-source Machine Learning–based Thick IOL Calculation FormulaAmerican Journal of Ophthalmology, 2021
- Update on Intraocular Lens Calculation FormulasOphthalmology, 2019
- Effect of altering lens constantsJournal of Cataract & Refractive Surgery, 2017
- Intraocular lens formula constant optimization and partial coherence interferometry biometry: Refractive outcomes in 8108 eyes after cataract surgeryJournal of Cataract & Refractive Surgery, 2011
- Prediction of the effective postoperative (intraocular lens) anterior chamber depthJournal of Cataract & Refractive Surgery, 2006
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisGraefe's Archive for Clinical and Experimental Ophthalmology, 2000
- The Hoffer Q formula: A comparison of theoretic and regression formulasJournal of Cataract & Refractive Surgery, 1993
- Comparison of the SRK/T formula and other theoretical and regression formulasJournal of Cataract & Refractive Surgery, 1990
- Development of the SRK/T intraocular lens implant power calculation formulaJournal of Cataract & Refractive Surgery, 1990