Spectrophotometer Ageing and Prediction of Fruit Attributes
- 1 January 2016
- journal article
- Published by SAGE Publications in Journal of Near Infrared Spectroscopy
- Vol. 24 (4) , 337-344
Abstract
Deterioration of lamp output quality over time and degradation of detector signal-to-noise ratio are issues associated with ageing of a spectrophotometer. To document the effect of instrument ageing on short wavelength near infrared spectroscopy-based assessment of internal attributes of fruit quality prediction (total soluble solids, TSS, of juice), an assessment was conducted of several handheld photodiode array-based spectrophotometers over several years, with repeated spectra of a reference Teflon (PTFE) tile and spectra of 20 apple fruit acquired at yearly intervals. The repeatability of each instrument was assessed as the standard deviation of absorbance of repeated measures of a reference, typically around 0.2 mAbs. Instrument changes were identified in performance and in principal components analysis plots, but performance (apple TSS model) was not related to instrument repeatability. A piecewise direct standardisation method is recommended to maintain a multivariate calibration model across spectrometers.Keywords
This publication has 19 references indexed in Scilit:
- Development of a Common Calibration Model for Determining the Brix Value of Intact Apple, Pear and Persimmon Fruits by near Infrared SpectroscopyJournal of Near Infrared Spectroscopy, 2014
- Temporal and Environmental Sensitivity of a Photodiode Array Spectrophometric SystemJournal of Near Infrared Spectroscopy, 2014
- A Review on the Applications of Portable Near-Infrared Spectrometers in the Agro-Food IndustryApplied Spectroscopy, 2013
- Temporal Sensitivity of the Wavelength Calibration of a Photodiode Array SpectrometerApplied Spectroscopy, 2010
- Framework for explicit drift correction in multivariate calibration modelsJournal of Chemometrics, 2010
- Calibration transfer between NIR diode array and FT-NIR spectrophotometers for measuring the soluble solids contents of applePostharvest Biology and Technology, 2007
- Robustness of Models Based on NIR Spectra for Sugar Content Prediction in ApplesJournal of Near Infrared Spectroscopy, 2003
- Transfer of multivariate calibration models: a reviewChemometrics and Intelligent Laboratory Systems, 2002
- Standardisation and Calibration Transfer for near Infrared Instruments: A ReviewJournal of Near Infrared Spectroscopy, 2001
- Optimization of Instrumentation Precision and Wavelength Resolution for the Performance of NIR Calibrations of Sucrose in a Water—Cellulose MatrixApplied Spectroscopy, 2000