Identification and sequence analysis of discordant phenotypes between AmpFlSTR SGM Plus™ and PowerPlex® 16
Authors:
- 4 April 2007
- journal article
- research article
- Published by Springer Nature in International journal of legal medicine
- Vol. 121 (4) , 297-301
Abstract
During duplicate analysis of buccal swabs from 1,377 individuals with 2 commercial short tandem repeat (STR) kits, we observed 8 discordant phenotypes with SGM Plus™ (SGM, second generation multiplex) for the STRs THO1 (2), vWA (4) and D18S51 (2), and 1 discrepancy with PowerPlex® 16 for D18S51. One individual even showed two discrepancies (vWA and THO1) for SGM Plus™. In each case, the difference observed was due to the non-amplification or allele dropout of the second allele in a heterozygous genotype. Sequence analysis revealed each time the presence of a mutation that probably coincided with the primer-binding site. Primer-binding site mutations for vWA and D18S51 have been reported previously, while the mutation for THO1 (C-to-T substitution at position 1286 of GenBank sequence D00269) is reported here for the first time. While the frequency of these silent alleles remains low (0.58% in our study), it is suggested that appropriate measures should be taken for database comparisons and that allelic dropout should be further investigated by sequence analysis and be reported to the forensic community.Keywords
This publication has 34 references indexed in Scilit:
- The Future of Forensic and Crime Scene Science: Part I. A UK forensic science user and provider perspectiveForensic Science International, 2006
- Allele Frequency Data for 19 Short Tandem Repeats (PowerPlex® 16 and FFFl) in a Belgian Population SampleJournal of Forensic Sciences, 2006
- Discovery and identification of new D13S317 primer binding site mutationsForensic Science International, 2006
- Y-chromosomal STR haplotypes in a Belgian population sample and identification of a micro-variant with a flanking site mutation at DYS19Forensic Science International, 2005
- Identification of more sequence variations in the D8S1179 locusForensic Science International, 2005
- Forensic DNA databasesForensic Science International, 2004
- False homozygosities at various loci revealed by discrepancies between commercial kits: implications for genetic databasesForensic Science International, 2004
- Belgian population data for 15 STR loci (AmpFlSTR® SGM Plus and AmpFlSTR™ profiler PCR amplification kit)Forensic Science International, 2004
- Primer binding site mutations affecting the typing of STR loci contained within the AMPFlSTR® SGM Plus™ kitForensic Science International, 2004
- STR primer concordance studyForensic Science International, 2001