A STUDY ON A TWO UNIT STANDBY SYSTEM WITH ERLANGIAN REPAIR TIME
Authors:
- 1 September 2004
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in Asia-Pacific Journal of Operational Research
- Vol. 21 (03) , 271-277
Abstract
A two-unit cold standby system is considered. The failure rate of a unit is a constant and the repair time distribution is a two-stage Erlang distribution. Measures of system performance such as reliability, mean time before failure, system availability, and steady-state availability are derived. Also, a consistent asymptotically normal estimator and a 100(1-α)% asymptotic confidence interval for the steady-state availability of the system are obtained.Keywords
This publication has 1 reference indexed in Scilit:
- Confidence limits for steady state availability of a two unit standby systemMicroelectronics Reliability, 1994