Abstract
Measuring the longest relaxation time of a viscoelastic liquid is an important step in its rheological characterization. In several instances, however, such measurement is unfeasible through conventional techniques, e.g., frequency response in linear viscoelasticity or measure of first normal stress difference. This difficulty is often found for very dilute macromolecular solutions. The case of polyelectrolyte solutions is especially important for their relevance in several bioengineering problems: Even theoretical predictions for this case can often not be tested in the absence of an experimental characterization. In this work, we succeed in measuring the relaxation time of two dilute/semidilute polyelectrolyte solutions as a function of added salt concentration. The relaxation time is measured through a novel microrheometrical technique based on the viscoelasticity-induced alignment of particles suspended in a microfluidic channel. We apply such technique to characterize two polyelectrolyte solutions, n...Keywords
This publication has 35 references indexed in Scilit:
- Microfluidic viscometers for shear rheology of complex fluids and biofluidsBiomicrofluidics, 2016
- Studying the effects of elongational properties on atomization of weakly viscoelastic solutions using Rayleigh Ohnesorge Jetting Extensional Rheometry (ROJER)Journal of Non-Newtonian Fluid Mechanics, 2015
- Rheometry-on-a-chip: measuring the relaxation time of a viscoelastic liquid through particle migration in microchannel flowsLab on a Chip, 2014
- Characterization of hyaluronic acid and synovial fluid in stagnation point elongational flowBiopolymers, 2013
- Serpentine channels: micro-rheometers for fluid relaxation timesLab on a Chip, 2013
- Is there a relation between the relaxation time measured in CaBER experiments and the first normal stress coefficient?Journal of Non-Newtonian Fluid Mechanics, 2010
- Microfluidic rheometryMechanics Research Communications, 2009
- Microfluidic rheometer based on hydrodynamic focusingMeasurement Science and Technology, 2008
- High shear rate viscometryRheologica Acta, 2008
- Tunable Nonlinear Viscoelastic “Focusing” in a Microfluidic DevicePhysical Review Letters, 2007