The direct analysis of fuel ethanol by ICP-MS using a flow injection system coupled to an ultrasonic nebulizer for sample introduction
- 14 August 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 21 (11) , 1340-1344
Abstract
In this work, a method for the analysis of fuel ethanol by ICP-MS is proposed. The direct introduction of a 10% v/v ethanol solution through an ultrasonic nebulizer formed carbon deposits on the cones. Therefore, a flow injection system was used to introduce 250 μL of the diluted sample or calibration solution. The optimized operational conditions were 1200 W RF power, 0.7 L min−1 nebulizer gas flow rate and 140 °C and −3 °C heating and cooling temperatures of the USN desolvation system. External calibration against aqueous solutions, matrix matching and isotope dilution (ID) were compared. The limits of detection were, in μg L−1, Ag: 0.08, Cd: 0.12, Co: 0.04, Cu: 0.4, Fe: 27, Mn: 0.7, Ni: 0.4 and Pb: 0.2, with calibration against aqueous solutions, and Ag: 0.02, Cd: 0.02, Cu: 0.2 and Pb: 0.04, with isotope dilution. Matrix matching was not recommended because of the carbon deposits formation. Both ID and calibration with aqueous solutions promoted speed, good precision, sensitivity and agreement with the results obtained by ETV-ICP-MS.Keywords
This publication has 27 references indexed in Scilit:
- Direct injection high efficiency nebulizer-inductively coupled plasma mass spectrometry for analysis of petroleum samplesSpectrochimica Acta Part B: Atomic Spectroscopy, 2003
- Trace element determination in crude oil and its fractions by inductively coupled plasma mass spectrometry using ultrasonic nebulization of toluene solutionsSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Determination of Cu, Mn, Ni and Sn in gasoline by electrothermal vaporization inductively coupled plasma mass spectrometry, and emulsion sample introductionSpectrochimica Acta Part B: Atomic Spectroscopy, 2002
- Comparison of the performance of FI-ICP-MS and FI-ETV-ICP-MS systems for the determination of trace elements in sea waterAnalytica Chimica Acta, 2001
- Comparison of an ultrasonic nebulizer with a cross-flow nebulizer for selenium speciation by ion-chromatography and inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2000
- Introduction of alcohols in inductively coupled plasma mass spectrometry by a flow injection systemAnalytica Chimica Acta, 1999
- Emprego de nebulizador pneumático de ICP-MS como câmara de diluição em sistemas de injeção em fluxo para determinações multielementaresQuímica Nova, 1998
- Greenhouse gas emissions and energy balances in bio-ethanol production and utilization in Brazil (1996)Biomass and Bioenergy, 1998
- Application of inductively coupled plasma source mass spectrometry (ICP-MS) to the determination of trace metals in organicsJournal of Analytical Atomic Spectrometry, 1986
- Flow injection analysesAnalytica Chimica Acta, 1975