The Effects of Vapor Space Height on the Vapor Chamber Performance
Authors:
- 17 January 2012
- journal article
- research article
- Published by Taylor & Francis in Experimental Heat Transfer
- Vol. 25 (1) , 1-11
Abstract
The performance of vapor chambers, also known as flat heat pipes, was studied experimentally. Five vapor chambers with different vapor space heights were intentionally fabricated and tested. The hydraulic diameter ratio was created to be the dimensionless parameter to represent the variation of the vapor space height. The parameter was further used to derive the optimum vapor chamber height. It was found that the vapor chamber achieved the optimum design when the hydraulic diameter ratio of non wick vapor space to chamber interior was greater than 0.6. It is believed that the results are valuable for future vapor chamber design.Keywords
This publication has 9 references indexed in Scilit:
- Experimental Investigation of Vapor Chamber Module Applied to High-Power Light-Emitting DiodesExperimental Heat Transfer, 2009
- Effect of Evaporator Section Lengths and Working Fluids on Operational Limit of Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV)American Journal of Applied Sciences, 2009
- Fabrication and thermal performance of a thin flat heat pipe with innovative sintered copper wick structure2006
- Capillary Limit of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers2006
- Investigation of a Novel Flat Heat PipeJournal of Heat Transfer, 2005
- High performance miniature heat pipeInternational Journal of Heat and Mass Transfer, 2002
- High heat flux heat pipe mechanism for cooling of electronicsIEEE Transactions on Components and Packaging Technologies, 2001
- Fundamental investigation of roll bond heat pipe as heat spreader plate for notebook computersIEEE Transactions on Components and Packaging Technologies, 2000
- Operating Characteristics of Loop Heat PipesSAE International Journal of Advances and Current Practices in Mobility, 1999