PhysioKit: Open-source, Low-cost Physiological Computing Toolkit for Single and Multi-user Studies
Preprint
- 7 August 2023
- preprint
- Published by MDPI AG in Preprints.org
Abstract
The proliferation of physiological sensors opens new opportunities to explore interactions, conduct experiments and evaluate the user experience with continuous monitoring of bodily functions. Commercial devices, however, can be costly or limit access to raw waveform data, while low-cost sensors are efforts-intensive to setup. To address these challenges, we introduce PhysioKit, an open-source, low-cost physiological computing toolkit. PhysioKit consists of (i) a sensor and hardware layer that can be configured in a modular manner per research needs, (ii) a software application layer that enables data acquisition, real-time visualization and machine learning (ML)-enabled signal quality assessment. This also supports basic visual biofeedback configurations and synchronized acquisition for co-located or remote multi-user settings. In a validation study for photo-plethysmography (PPG) sensor with 15 participants, PhysioKit shows strong agreement with research-grade PPG sensors. Furthermore, we report usability survey results from 10 micro-project teams (44 individual members in total) who use PhysioKit for 4-6 weeks, providing insights into its use cases and research benefits. We conclude by discussing extensibility and potential impact of the toolkit on the research community.Keywords
All Related Versions
This publication has 86 references indexed in Scilit:
- Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial FibrillationJACC: Clinical Electrophysiology, 2023
- Using Wearable Devices for Emotion Recognition in Mobile Human- Computer Interaction: A Review2022
- Deep convolutional neural network-based signal quality assessment for photoplethysmogramComputers in Biology and Medicine, 2022
- A Survey on Wearable Technology: History, State-of-the-Art and Current ChallengesComputer Networks, 2021
- Investigating sources of inaccuracy in wearable optical heart rate sensorsnpj Digital Medicine, 2020
- RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exerciseEuropean Journal of Applied Physiology, 2019
- Benchmarking of the BITalino biomedical toolkit against an established gold standardHealthcare Technology Letters, 2019
- Feeling validated yet? A scoping review of the use of consumer-targeted wearable and mobile technology to measure and improve sleepSleep Medicine Reviews, 2018
- Remote patient monitoring: a comprehensive studyJournal of Ambient Intelligence and Humanized Computing, 2017
- Accuracy of the Garmin 920 XT HRM to perform HRV analysisAustralasian Physics & Engineering Sciences in Medicine, 2017