An In Vivo Evaluation of Four Spinal Needles Used for the Combined Spinal-Epidural Technique
Authors:
- C. H. HerbstmanCHC. H. Herbstman
- J. B. JaffeeJJJ. B. Jaffee
- K. J. TumanKTK. J. Tuman
- L. M. NewmanLNL. M. Newman
- 1 March 1998
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 86 (3) , 520-522
Abstract
Le (Becton-Dickinson [B-D] 27-gauge, 119-mm Whitacre; B-D 27-gauge, 120-mm Durasafe[trademark symbol]; B-D 25-gauge, 120-mm Durasafe[trademark symbol]; or International Medical Devices' 26-gauge, 124-mm Gertie Marx[trademark symbol]). Success in obtaining cerebrospinal fluid (CSF) and the incidence of transient paresthesias and postdural puncture headache (PDPH) were compared by using chi squared testing; P < 0.05 was considered significant. Failure to obtain CSF (3%-5%) was not significantly different among spinal needles. The Gertie Marx[trademark symbol] 26-gauge needle was associated with significantly more paresthesias (29%) than the Whitacre 27-gauge needle (17%). The combined incidence of paresthesias with the Durasafe[trademark symbol] 25-gauge and Gertie Marx[trademark symbol] 26-gauge spinal needles (28%) was greater than the combined incidence of paresthesias with the Durasafe[trademark symbol] 27-gauge and Whitacre 27-gauge needles (18%). The incidence of PDPH did not differ among the four pencil-point spinal needles. We conclude that longer spinal needles are associated with a significantly more frequent incidence of transient paresthesias without residual effects. Implications: The use of four pencil-point spinal needles in the combined spinal-epidural technique is associated with an inconsequential incidence of spinal headache, a low incidence of paresthesias that are transient with no long-term effects, and a high degree of success independent of spinal needle length. (Anesth Analg 1998;86:520-2)...Keywords
This publication has 7 references indexed in Scilit:
- Cerebrospinal Fluid Leakage, Spinal Needles, and Postdural Puncture Headache (PDPH)Anesthesia & Analgesia, 1995
- Cerebrospinal Fluid Leakage, Spinal Needles, and Postdural Puncture Headache (PDPH)Anesthesia & Analgesia, 1995
- Comparison of the Force Required for Dural Puncture with Different Spinal Needles and Subsequent Leakage of Cerebrospinal FluidAnesthesia & Analgesia, 1994
- Complications of Labor AnalgesiaAnesthesia & Analgesia, 1994
- Combined spinal epidural (CSE) analgesia: technique, management, and outcome of 300 mothersInternational Journal of Obstetric Anesthesia, 1994
- An evaluation of a combined spinal/epidural needle set utilising a 26‐gauge, pencil point spinal needle for Caesarean sectionAnaesthesia, 1992
- More on combined subarachnoid and epidural techniquesAnaesthesia, 1986