Custom Array Comparative Genomic Hybridization: the Importance of DNA Quality, an Expert Eye, and Variant Validation
Open Access
- 10 March 2017
- journal article
- research article
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 18 (3) , 609
Abstract
The presence of false positive and false negative results in the Array Comparative Genomic Hybridization (aCGH) design is poorly addressed in literature reports. We took advantage of a custom aCGH recently carried out to analyze its design performance, the use of several Agilent aberrations detection algorithms, and the presence of false results. Our study provides a confirmation that the high density design does not generate more noise than standard designs and, might reach a good resolution. We noticed a not negligible presence of false negative and false positive results in the imbalances call performed by the Agilent software. The Aberration Detection Method 2 (ADM-2) algorithm with a threshold of 6 performed quite well, and the array design proved to be reliable, provided that some additional filters are applied, such as considering only intervals with average absolute log2ratio above 0.3. We also propose an additional filter that takes into account the proportion of probes with log2ratio exceeding suggestive values for gain or loss. In addition, the quality of samples was confirmed to be a crucial parameter. Finally, this work raises the importance of evaluating the samples profiles by eye and the necessity of validating the imbalances detected.Keywords
Funding Information
- Italian Ministry of Health "Giovani Ricercatori" (GR-2011-02347381)
This publication has 39 references indexed in Scilit:
- Identification of familial and de novo microduplications of 22q11.21-q11.23 distal to the 22q11.21 microdeletion syndrome regionHuman Molecular Genetics, 2009
- The Fine-Scale and Complex Architecture of Human Copy-Number VariationThe American Journal of Human Genetics, 2008
- The identification of microdeletion syndromes and other chromosome abnormalities: Cytogenetic methods of the past, new technologies for the futureAmerican Journal of Medical Genetics Part C: Seminars in Medical Genetics, 2007
- Evaluation of a commercially available focused aCGH platform for the detection of constitutional chromosome anomaliesAmerican Journal of Medical Genetics Part A, 2007
- Discovery of a previously unrecognized microdeletion syndrome of 16p11.2–p12.2Nature Genetics, 2007
- Array CGH analysis of copy number variation identifies 1284 new genes variant in healthy white males: implications for association studies of complex diseasesHuman Molecular Genetics, 2007
- A Comprehensive Analysis of Common Copy-Number Variations in the Human GenomeThe American Journal of Human Genetics, 2007
- Global variation in copy number in the human genomeNature, 2006
- Discovery of previously unidentified genomic disorders from the duplication architecture of the human genomeNature Genetics, 2006
- Detection of large-scale variation in the human genomeNature Genetics, 2004