Abstract
High-flexion total knee replacement (TKR) designs have been introduced to improve flexion after TKR. Although the early results of such designs were promising, recent literature has raised concerns about the incidence of early loosening of the femoral component. We compared the minimum force required to cause femoral component loosening for six high-flexion and six conventional TKR designs in a laboratory experiment. Each TKR design was implanted in a femoral bone model and placed in a loading frame in 135° of flexion. Loosening of the femoral component was induced by moving the tibial component at a constant rate of displacement while maintaining the same angle of flexion. A stereophotogrammetric system registered the relative movement between the femoral component and the underlying bone until loosening occurred. Compared with high-flexion designs, conventional TKR designs required a significantly higher force before loosening occurred (p < 0.001). High-flexion designs with closed box geometry required significantly higher loosening forces than high-flexion designs with open box geometry (p = 0.0478). The presence of pegs further contributed to the fixation strength of components. We conclude that high-flexion designs have a greater risk for femoral component loosening than conventional TKR designs. We believe this is attributable to the absence of femoral load sharing between the prosthetic component and the condylar bone during flexion.Keywords
This publication has 26 references indexed in Scilit:
- Does the new generation of high-flex knee prostheses improve the post-operative range of movement?The Journal of Bone and Joint Surgery. British volume, 2010
- The Role of Polyethylene Design on Postoperative TKA Flexion: An Analysis of 1534 CasesClinical Orthopaedics and Related Research, 2010
- A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion componentsThe Journal of Bone and Joint Surgery. British volume, 2008
- High-flexion TKA DesignsClinical Orthopaedics and Related Research, 2007
- The Early Results of High-Flex Total Knee Arthroplasty: A Minimum of 2 Years of Follow-upThe Journal of Arthroplasty, 2005
- Does Total Knee Replacement Restore Normal Knee Function?Clinical Orthopaedics and Related Research, 2005
- Knee Motions During Maximum Flexion in Fixed and Mobile-Bearing ArthroplastiesClinical Orthopaedics and Related Research, 2003
- Maximizing flexion after total knee arthroplasty: The need and the pitfallsThe Journal of Arthroplasty, 2002
- Range of Motion in Total Knee ReplacementClinical Orthopaedics and Related Research, 1996
- Patient Outcomes Following Tricompartmental Total Knee ReplacementJAMA, 1994