Radiological characterization and water equivalency of genipin gel for x-ray and electron beam dosimetry
Authors:
- Robin HillRHRobin Hill
- Zdenka KuncicZKZdenka Kuncic
- Stephen BosiSBStephen Bosi
- Justin B DaviesJDJustin B Davies
- Clive BaldockCBClive Baldock
- 6 July 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (15) , 4685-4699
Abstract
The genipin radiochromic gel offers enormous potential as a three-dimensional dosimeter in advanced radiotherapy techniques. We have used several methods (including Monte Carlo simulation), to investigate the water equivalency of genipin gel by characterizing its radiological properties, including mass and electron densities, photon interaction cross sections, mass energy absorption coefficient, effective atomic number, collisional, radiative and total mass stopping powers and electron mass scattering power. Depth doses were also calculated for clinical kilovoltage and megavoltage x-ray beams as well as megavoltage electron beams. The mass density, electron density and effective atomic number of genipin were found to differ from water by less than 2%. For energies below 150 keV, photoelectric absorption cross sections are more than 3% higher than water due to the strong dependence on atomic number. Compton scattering and pair production interaction cross sections for genipin gel differ from water by less than 1%. The mass energy absorption coefficient is approximately 3% higher than water for energies <60 keV due to the dominance of photoelectric absorption in this energy range. The electron mass stopping power and mass scattering power differ from water by approximately 0.3%. X-ray depth dose curves for genipin gel agree to within 1% with those for water. Our results demonstrate that genipin gel can be considered water equivalent for kilovoltage and megavoltage x-ray beam dosimetry. For megavoltage electron beam dosimetry, however, our results suggest that a correction factor may be needed to convert measured dose in genipin gel to that of water, since differences in some radiological properties of up to 3% compared to water are observed. Our results indicate that genipin gel exhibits greater water equivalency than polymer gels and PRESAGE formulations.Keywords
This publication has 45 references indexed in Scilit:
- Investigation of radiological properties and water equivalency of PRESAGE® dosimetersMedical Physics, 2011
- Water equivalency evaluation of PRESAGE®dosimeters for dosimetry of Cs-137 and Ir-192 brachytherapy sourcesJournal of Physics: Conference Series, 2010
- Study of dosimetric water equivalency of PRESAGE®for megavoltage and kilovoltage x-ray beamsJournal of Physics: Conference Series, 2010
- The characterisation of a genipin-gelatin gel dosimeterJournal of Physics: Conference Series, 2010
- Polymer gel dosimetryPhysics in Medicine & Biology, 2010
- Radiological properties of the PRESAGE and PAGAT polymer dosimetersApplied Radiation and Isotopes, 2008
- Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECTApplied Radiation and Isotopes, 2008
- Water equivalent plastic scintillation detectors in radiation therapyRadiation Protection Dosimetry, 2006
- An in vivo evaluation of a biodegradable genipin-cross-linked gelatin peripheral nerve guide conduit materialBiomaterials, 2005
- Terpenoids. XLVII.1 The Structure of Genipin2The Journal of Organic Chemistry, 1961