The Effect of Screw Pullout Rate on Screw Purchase in Synthetic Cancellous Bone
Authors:
- 10 December 2008
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 131 (2) , 024501
Abstract
Clinically, orthopaedic fracture fixation constructs are mounted using screws inserted into cancellous bone, while biomechanical studies are increasingly using commercially available synthetic bones. The goal of this study was to examine the effect of screw pullout rate on cancellous bone screw purchase strength in synthetic cancellous bone. Sixty synthetic cancellous bone cubes (40×40×40mm3) each had one orthopaedic cancellous bone screw (major diameter=6.5mm) inserted to a depth of 30mm. Screws were extracted to obtain outcome measures of failure force, failure shear stress, failure energy, failure displacement, resistance force, and removal energy. The ten test groups (n=6 cubes per group) had screws extracted at pullout rates of 1mm∕min, 2.5mm∕min, 5mm∕min, 7.5mm∕min, 10mm∕min, 20mm∕min, 30mm∕min, 40mm∕min, 50mm∕min, and 60mm∕min. The aggregate average results for failure force, failure stress, failure energy, failure displacement, resistance force, and postfailure removal energy for combined pullout rates were, respectively, 984.8±63.9N, 3.5±0.2MPa, 298.3±41.7J, 0.53±0.08mm, 453.8±19.6N, and 5420.1±489.7J. Most statistical differences (40 of 47) involved either the 5mm∕min or the 60mm∕min rates being compared to other rates. Failure force, failure stress, and resistance force increased and were highly linearly correlated with pullout rate (R2=0.78, 0.76, and 0.74, respectively). Failure energy, failure displacement, and removal energy were relatively unchanged over the pullout range tested, yielding low correlation coefficients (R2<0.05). Failure force, failure stress, and resistance force were affected by bone screw pullout rate in synthetic cancellous bone, while failure energy, failure displacement, and removal energy remained unchanged. This is the first study to perform an extensive investigation of cancellous bone screw pullout rate in synthetic cancellous bone.Keywords
This publication has 32 references indexed in Scilit:
- The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic FemursJournal of Biomechanical Engineering, 2006
- An In Vitro Biomechanical Comparison of the Insertion Variables and Pullout Mechanical Properties of AO 6.5‐mm Standard Cancellous and 7.3‐mm Self‐Tapping, Cannulated Bone Screws in Foal Femoral BoneVeterinary Surgery, 2004
- Unstable Proximal Extraarticular Tibia FracturesJournal of Orthopaedic Trauma, 2004
- Impaction bone-grafting increases the holding power of cancellous screws in the femoral head : A pull-out study in human cadaver hipsActa Orthopaedica, 1999
- Factors Affecting the Pullout Strength of Cancellous Bone ScrewsJournal of Biomechanical Engineering, 1996
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996
- Fixation pull-out response measurement of bone screws and porous-surfaced postsJournal of Biomechanics, 1994
- Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplastyJournal of Orthopaedic Research, 1992
- Holding Power of Orthopedic Screws in Equine Third Metacarpal and Metatarsal Bones: Part II. Adult Horse BoneVeterinary Surgery, 1985
- Holding power of different screws in the femoral head: A study in human cadaver hipsActa Orthopaedica, 1984