Locations of High Contact Force During Left Atrial Mapping in Atrial Fibrillation Patients
- 1 August 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 6 (4) , 746-753
Abstract
Background—: During radiofrequency ablation, high electrode-tissue contact force (CF) is associated with increased risk of steam pop and perforation. The purpose of this study, in patients undergoing ablation of paroxysmal atrial fibrillation, was to: (1) identify factors producing high CF during left atrial (LA) and pulmonary vein mapping; (2) determine the ability of atrial potential amplitude and impedance to predict CF; and (3) explore the feasibility of controlling radiofrequency power based on CF. Methods and Results—: A high-density map of LA/pulmonary veins (median 328 sites) was obtained in 18 patients undergoing atrial fibrillation ablation using a 7.5-Fr irrigated mapping/ablation catheter to measure CF. Average CF was displayed on the 3D map. For 5682 mapped sites, CF ranged 1–144 g (median 8.2 g). High CF (≥35 g) was observed at only 118/5682 (2%) sites, clustering in 6 LA regions. The most common high CF site (48/113 sites in 17/18 patients) was located at the anterior/rightward LA roof, directly beneath the ascending aorta (confirmed by merging the CT image and map). Poor relationship between CF and either unipolar amplitude, bipolar amplitude, or impedance was observed. During ablation, radiofrequency power was modulated based on CF. All pulmonary veins were isolated without steam pop, impedance rise, or pericardial effusion. Conclusions—: High CF often occurs at anterior/rightward roof, where the ascending aorta provides resistance to the LA. Atrial potential amplitude and impedance are poor predictors of CF. Controlling radiofrequency power based on CF seems to prevent steam pop and impedance rise without loss of lesion effectiveness.Keywords
This publication has 12 references indexed in Scilit:
- A novel radiofrequency ablation catheter using contact force sensing: Toccata studyHeart Rhythm, 2012
- Area Under the Real‐Time Contact Force Curve (Force–Time Integral) Predicts Radiofrequency Lesion Size in an In Vitro Contractile ModelJournal of Cardiovascular Electrophysiology, 2010
- Relationship Between Catheter Forces, Lesion Characteristics, “Popping,” and Char Formation: Experience with Robotic Navigation SystemJournal of Cardiovascular Electrophysiology, 2009
- Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and ThrombusCirculation: Arrhythmia and Electrophysiology, 2008
- Electrode Impedance: An Indicator of Electrode-Tissue Contact and Lesion Dimensions During Linear AblationJournal of Interventional Cardiac Electrophysiology, 2000
- The LETR‐Principle: A Novel Method to Assess Electrode‐Tissue Contact in Radiofrequency AblationJournal of Cardiovascular Electrophysiology, 1998
- The Effects of Electrode‐Tissue Contact on Radiofrequency Lesion GenerationPacing and Clinical Electrophysiology, 1997
- Effects of dispersive electrode position and surface area on electrical parameters and temperature during radiofrequency catheter ablationThe American Journal of Cardiology, 1996
- Relation between impedance and endocardial contact during radiofrequency catheter ablationAmerican Heart Journal, 1994
- Determinants of Lesion Size During Radiofrequency Catheter Ablation: The Role of Electrode‐Tissue Contact Pressure and Duration of Energy DeliveryJournal of Cardiovascular Electrophysiology, 1991