The fracture toughness of dental composites
Author:
- 1 March 1982
- journal article
- research article
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 9 (2) , 133-138
Abstract
Summary: A fracture mechanics approach has been adopted to quantify the failure of dental composites under stress. The parameter KIC has been determined by the use of SEN specimens subject to the variables of composite product type, storage environment, test environment and temperature, and polymerization time. The results show that KIc varies from product to product, increasing significantly if there is sufficient time for the absorption of storage water. The effect of test environment and temperature (over the range expected in vivo) is minor.Keywords
This publication has 7 references indexed in Scilit:
- The fracture toughness of dental compositesJournal of Oral Rehabilitation, 1982
- The effect of temperature on the fracture of polycarbonateJournal of Materials Science, 1975
- Time-temperature dependent fracture toughness of PMMAJournal of Materials Science, 1975
- Failure of brittle polymers by slow crack growthJournal of Materials Science, 1975
- Temperature effects in the fracture of PMMAJournal of Materials Science, 1974
- Fracture energy of an epoxy composite systemJournal of Materials Science, 1971
- Fracture processes in polymeric materials. VII. The nature of local inelastic processes in glassy polymersJournal of Polymer Science Part A: General Papers, 1965