Evaluation of New Plate Designs for Symphysis Pubis Internal Fixation
Authors:
- 1 September 1996
- journal article
- research article
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 41 (3) , 498-502
Abstract
The purpose of this study was to evaluate and compare biplanar and other newly designed plates used for pubic symphysis internal fixation to other standard plates. Our data demonstrate that neither of the newly designed symphyseal plates, curved (Zimmer four-hole plate with either two or four 4.5-mm cortical screws) nor the biplanar (Zimmer six-hole plate with four 4.5-mm cortical screws in one plane and two 4.5-mm cortical screws in another) significantly reduce motion more than the other plates tested (Synthes two-hole 4.5-mm dynamic compression plate with two 6.5-mm cancellous screws and six-hole 3.5-mm reconstruction plate with four 3.5-mm cortical screws). All of the plate constructs were able to restore motion to nearly that of the intact symphysis pubis and sacroiliac joint. In summary, using the anteroposterior compression disruption pattern and model, the disrupted symphysis does gap under load but has no effect on sacroiliac joint gapping. It does permit increase in relative flexion angles between the wings of the pelvis. All of the plate systems tested restore normal gap motion at the symphysis and normal sacroiliac joint flexion.Keywords
This publication has 13 references indexed in Scilit:
- Box Plate Fixation of the Symphysis Pubis: Biomechanical Evaluation of a New TechniqueJournal of Orthopaedic Trauma, 1994
- Internal Fixation of the Unstable Anterior Pelvic Ring: A Biomechanical Comparison of Standard Plating Techniques and the Retrograde Medullary Superior Pubic Ramus ScrewJournal of Orthopaedic Trauma, 1994
- Biomechanical Testing of New and Old Fixation Devices for Vertical Shear Fractures of the PelvisJournal of Orthopaedic Trauma, 1991
- Pelvic Ring Disruptions1990
- Two-hole Plate Fixation for Traumatic Symphysis Pubis Diastasis1988
- Pelvic ring fractures: should they be fixed?The Journal of Bone and Joint Surgery. British volume, 1988
- Pelvic fractures: value of plain radiography in early assessment and management.Radiology, 1986
- Dynamic performance characteristics of the liquid metal strain gageJournal of Biomechanics, 1986
- Mobility of the pubic symphysis: Measurements by an electromechanical methodActa Orthopaedica, 1984
- Pelvic Fractures: Operative Versus Nonoperative TreatmentOrthopedic Clinics of North America, 1980