Quantification of visceral perfusion and impact of femoral cannulation: in vitro model of aortic dissection
- 17 December 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
Abstract
OBJECTIVES: We aimed to simulate blood flow at an aortic dissection in an in vitro vascular model and assess the impact of the cannulation method on visceral perfusion. METHODS: An aortic-dissection model with an acrylic aortic wall and silicone intimal flap was developed to study visceral perfusion under various cannulation conditions. The primary tear was placed in the proximal descending aorta and the re-entry site in the left common iliac artery. A cardiovascular pump was used to reproduce a normal pulsatile aortic flow and a steady cannulation flow. Axillary and axillary plus femoral cannulation were compared at flow rates of 3–7 l/min. Haemodynamics were analysed by using four-dimensional flow magnetic resonance imaging. RESULTS: Axillary cannulation (AC) was found to collapse the true lumen at the coeliac and superior mesentery arteries, while combined axillary and femoral cannulation did not change the size of the true lumen. Combined axillary and femoral cannulation resulted in a larger visceral flow than did AC alone. When axillary plus femoral cannulation was used, the visceral flow increased by 125% at 3 l/min, by 89% at 4 l/min, by 67% at 5 L/min, by 98% at 6 l/min and by 101% at 7 l/min, respectively, compared to those with the AC only. CONCLUSIONS: Our model was useful to understanding the haemodynamics in aortic dissection. In this specific condition, we confirmed that the intimal flap motion can partially block blood flow to the coeliac and superior mesenteric arteries and that additional femoral cannulation can increase visceral perfusion.Keywords
Funding Information
- National Research Foundation of Korea
- Ministry of Education (NRF-2018R1D1A1B07049387, NRF-2020R1G1A1006418, NRF-2020R1A4A1019475)
This publication has 26 references indexed in Scilit:
- Acute type B aortic dissection complicated by visceral ischemiaThe Journal of Thoracic and Cardiovascular Surgery, 2015
- Malperfusion Syndrome Without Organ Failure Is Not a Risk Factor for Surgical Procedures for Type A Aortic DissectionThe Annals of Thoracic Surgery, 2014
- Effects of intermittent lower body perfusion on end-organ function during repair of acute DeBakey type I aortic dissection under moderate hypothermic circulatory arrestEuropean Journal of Cardio-Thoracic Surgery, 2013
- Clinical presentation, management, and short-term outcome of patients with type A acute dissection complicated by mesenteric malperfusion: Observations from the International Registry of Acute Aortic DissectionThe Journal of Thoracic and Cardiovascular Surgery, 2013
- A blood-mimicking fluid for particle image velocimetry with silicone vascular modelsExperiments in Fluids, 2010
- Rapid and safe establishment of cardiopulmonary bypass in repair of acute aortic dissection: improved results with double cannulationInteractive CardioVascular and Thoracic Surgery, 2008
- Significance of malperfusion syndromes prior to contemporary surgical repair for acute type A dissection: outcomes and need for additional revascularizationsEuropean Journal of Cardio-Thoracic Surgery, 2007
- Passive mechanical properties and structure of the aorta: segmental analysisActa Physiologica, 2007
- Femoral Cannulation is Safe for Type A Dissection RepairThe Annals of Thoracic Surgery, 2004