A quality assurance tool for high‐dose‐rate brachytherapy
Authors:
- Daniel W. RickeyDRDaniel W. Rickey
- David SasakiDSDavid Sasaki
- Jeff BewsJBJeff Bews
- 12 May 2010
- journal article
- Published by Wiley in Medical Physics
- Vol. 37 (6Part1) , 2525-2532
Abstract
Purpose: The purpose of this work was to develop a quality assurance (QA) tool for high‐dose‐rate (HDR) brachytherapy that would quickly and easily verify both source positioning (dwell positions) and durations (dwell times).Methods: The authors constructed a QA tool that combined radiochromic film to verify position with four photodiode detectors to verify dwell times. To characterize the temporal accuracy of the tool, a function generator powered four red light‐emitting diodes that were optically coupled to the four photodiode detectors. The QA tool was used to verify the dwell positions and times of a commercial brachytherapy afterloader. Measurements of dwell time were independently verified by a one‐dimensional optical camera that acquired 1000 lines/s.Results: The temporal accuracy of the QA tool was found to be about 1 ms. For visual assessment, the source position could be located within about 0.5 mm. Evaluating the accuracy and precision of an HDR brachytherapy afterloader, the authors found that the bias in dwell time can exceed 60 ms and the dwell time associated with the first dwell position had an unexpectedly large standard deviation of 30 ms. They found that the source locations were much easier to locate on the film if a plastic catheter was used instead of a metal treatment tube. Scanning the films enabled the dwell positions to be determined within about 0.2 mm.Conclusions: For pretreatment QA, the authors found that this tool allowed verification of dwell positions and dwell times in about 6 min.Keywords
This publication has 23 references indexed in Scilit:
- Review of MammoSite brachytherapy: Advantages, disadvantages and clinical outcomesActa Oncologica, 2009
- High dose rate brachytherapy for prostate cancerCancer/Radiothérapie, 2008
- Transit dose contributions to intracavitary and interstitial PDR brachytherapy treatmentsPhysics in Medicine & Biology, 2008
- High dose-rate brachytherapy source position quality assurance using radiochromic filmMedical Dosimetry, 2007
- Comparison of dosimetric standards of USA and France for HDR brachytherapyPhysics in Medicine & Biology, 2005
- A dwell position verification method for high dose rate brachytherapyJournal of Applied Clinical Medical Physics, 2004
- Spectral response of a gamma and electron irradiated pin photodiodeIEEE Transactions on Nuclear Science, 2002
- High‐Dose‐Rate Brachytherapy in the Treatment of Recurrent and Residual Head and Neck CancerThe Laryngoscope, 2002
- The use of radiochromic film to measure dose distributions resulting from high dose rate 192iridium single catheter treatmentsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1996
- Quality assurance tool for high dose rate brachytherapyMedical Physics, 1995