The measurement of the total volume of red cells in man: a non-radioactive approach using biotin
Authors:
- D. TrevettDTD. Trevett
- J. FisherJFJ. Fisher
- T. HoyTHT. Hoy
- 1 December 1988
- journal article
- research article
- Published by Wiley in British Journal of Haematology
- Vol. 70 (4) , 491-493
Abstract
Present methods for measuring red cell volume are based on the dilution of radioactively labelled cells. This precludes the investigation in neonates and pregnant women. We present a simple method for labelling red cells with biotin. These cells may be injected intravenously and subsequently detected using streptavidin-FITC and flow-cytometry. A comparison of the red cell volume estimated using both 51Cr and biotin labelled cells in 19 patients showed no consistent clinically significant difference between the two. This novel label appears to allow red volume to be reliably estimated without using radioactivity.Keywords
This publication has 5 references indexed in Scilit:
- Lessons from the Anemia of PrematurityHematology/Oncology Clinics of North America, 1987
- Biotinylated erythrocytes: in vivo survival and in vitro recoveryBlood, 1987
- Radiation protection: Natural radiation risksNature, 1983
- Biotin in clinical medicine—a reviewThe American Journal of Clinical Nutrition, 1981
- Red cell volume measurements and acute blood loss in high-risk newborn infantsThe Journal of Pediatrics, 1977