Radiopacity evaluation of Portland and MTA-based cements by digital radiographic system
Open Access
- 1 June 2011
- journal article
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 19 (3) , 228-232
Abstract
The aim of the present study was to evaluate the radiopacity of Portland and MTA-based cements using the Digora TM digital radiographic system. The performed tests followed specification number 57 from the American National Standard Institute/American Dental Association (2000) for endodontic sealing materials. The materials were placed in 5 acrylic plates, especially designed for this experiment, along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The set was radiographed at a 30 cm focus-object distance and with 0.2 s exposure time. After the radiographs were taken, the optical laser readings of radiographs were performed by Digora TM system. Five radiographic density readings were performed for each studied material and for each step of the aluminum scale. White ProRoot MTA (155.99±8.04), gray ProRoot MTA (155.96±16.30) and MTA BIO (143.13±16.94) presented higher radiopacity values (p<0.05), while white non-structural Portland (119.76±22.34), gray Portland (109.71±4.90) and white structural Portland (99.59±12.88) presented lower radiopacity values (p<0.05). It was concluded that MTA-based cements were the only materials presenting radiopacity within the ANSI/ADA specifications.Keywords
This publication has 24 references indexed in Scilit:
- Radiopacity of Portland Cement Associated With Different Radiopacifying AgentsJournal of Endodontics, 2009
- Effect of Selected Accelerants on the Physical Properties of Mineral Trioxide Aggregate and Portland CementJournal of Endodontics, 2007
- Radiopacity of Endodontic Materials on Film and a Digital SensorJournal of Endodontics, 2007
- Comparative chemical study of MTA and portland cementsBrazilian Dental Journal, 2007
- Comparison of the Physical and Mechanical Properties of MTA and Portland CementJournal of Endodontics, 2006
- In vitro biocompatibility tests of two commercial types of mineral trioxide aggregateBrazilian Oral Research, 2005
- A standard for radiopacity of root‐end (retrograde) filling materials is urgently neededInternational Endodontic Journal, 2004
- MTA for Obturation of Mandibular Central Incisors with Open Apices: Case ReportJournal of Endodontics, 2004
- Mineral Trioxide Aggregate (MTA) Solubility and Porosity with Different Water-to-Powder RatiosJournal of Endodontics, 2003
- A Comparative Analysis Of Mineral Trioxide Aggregate And Portland CementAustralian Endodontic Journal, 2003