PSF reconstruction for Compton-based prompt gamma imaging
- 25 January 2018
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 63 (3) , 035015
Abstract
Compton-based prompt gamma (PG) imaging has been proposed for in vivo range verification in proton therapy. However, several factors degrade the image quality of PG images, some of which are due to inherent properties of a Compton camera such as spatial resolution and energy resolution. Moreover, Compton-based PG imaging has a spatially variant resolution loss. In this study, we investigate the performance of the list-mode ordered subset expectation maximization algorithm with a shift-variant point spread function (LM-OSEM-SV-PSF) model. We also evaluate how well the PG images reconstructed using an SV-PSF model reproduce the distal falloff of the proton beam. The SV-PSF parameters were estimated from simulation data of point sources at various positions. Simulated PGs were produced in a water phantom irradiated with a proton beam. Compared to the LM-OSEM algorithm, the LM-OSEM-SV-PSF algorithm improved the quality of the reconstructed PG images and the estimation of PG falloff positions. In addition, the 4.44 and 5.25 MeV PG emissions can be accurately reconstructed using the LM-OSEM-SV-PSF algorithm. However, for the 2.31 and 6.13 MeV PG emissions, the LM-OSEM-SV-PSF reconstruction provides limited improvement. We also found that the LM-OSEM algorithm followed by a shift-variant Richardson–Lucy deconvolution could reconstruct images with quality visually similar to the LM-OSEM-SV-PSF-reconstructed images, while requiring shorter computation time.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 106-2221-E-002-235)
- Chang Gung Memorial Hospital, Linkou (BMRPE33)
- Dose Assessment Core Laboratory of Institute for Radiological Research
This publication has 38 references indexed in Scilit:
- Proton therapy monitoring by Compton imaging: influence of the large energy spectrum of the prompt-γradiationPhysics in Medicine & Biology, 2016
- Acceleration of image-based resolution modelling reconstruction using an expectation maximization nested algorithmPhysics in Medicine & Biology, 2013
- DETECTION AND IMAGING OF THE CRAB NEBULA WITH THE NUCLEAR COMPTON TELESCOPEThe Astrophysical Journal, 2011
- Non-Gaussian space-variant resolution modelling for list-mode reconstructionPhysics in Medicine & Biology, 2010
- A Tracking Compton-Scattering Imaging System for Hadron Therapy MonitoringIEEE Transactions on Nuclear Science, 2010
- Optimisation of a dual head semiconductor Compton camera using Geant4Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- Effect of position resolution on LoR discrimination for a dual-head Compton cameraNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- Effect of176Lu background on singles transmission for LSO-based PET camerasPhysics in Medicine & Biology, 2002
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- A Quantum Theory of the Scattering of X-rays by Light ElementsPhysical Review B, 1923