Abstract
Structural Health Monitoring (SHM) is a process of detecting damages to engineering structures. The goal of SHM is to improve both the safety and reliability of infrastructures such as buildings, bridges, and highways. Several efforts have been made to develop improved SHM systems. However, most of these studies only considered vibration as a monitoring parameter without incorporating expert systems based on fuzzy inference. In this work, an expert system was incorporated into SHM for monitoring residential buildings based on building temperature and vibration measurements. The developed system used a Wireless Sensor Network (WSN) with a 2.4 GHz Radio Frequency (RF) band. Results of the system performance evaluation indicated a decrease in reliability from 99% to 50% within a decade of its deployment. In terms of energy conservation, results showed that the system was able to save 30% of energy, thereby increasing its lifetime. The fuzzy expert SHM system is able to detect building conditions with a good level of reliability, energy conservation capability and high accuracy of 94.4% and 100% as the least and best performance, respectively. Hence, direct integration of this system into building structures could aid early detection of building impairment.Keywords
This publication has 24 references indexed in Scilit:
- Kappa-PSO-FAN based method for damage identification on composite structural health monitoringExpert Systems with Applications, 2018
- An Embedded Fuzzy Logic Based Application for Density Traffic Control SystemInternational Journal of Artificial Intelligence Research, 2018
- Structural health monitoring system using IOT and wireless technologies2017
- Introduction to Fuzzy Systems2017
- Structural health monitoring: Internet of things application2017
- TDR-based monitoring of rising damp through the embedding of wire-like sensing elements in building structuresMeasurement, 2017
- Vibration health monitoring for tensegrity structuresMechanical Systems and Signal Processing, 2017
- Fibre Optic Sensors for the Structural Health Monitoring of Building StructuresProcedia Technology, 2016
- A hybrid immune model for unsupervised structural damage pattern recognitionExpert Systems with Applications, 2011
- Fuzzy Logic Control—A TutorialIETE Technical Review, 1991