Development and benchtop testing of an aptamer-based sweat sensor for CRP detection
Authors:
- 30 October 2025
- journal article
- research article
- Published by Springer Nature in Microchimica Acta
- Vol. 192 (11) , 1-13
Abstract
The development of an assay is presented for an aptamer-based flexible sensor aimed at the non-invasive detection of C-reactive protein in sweat that is passively perspired. CRP is a well-preserved plasma protein and a homopentameric acute-phase inflammatory protein crucial to the body’s inflammatory responses. A significant advancement in this platform is the incorporation of aptamers, which provide notable benefits compared to conventional antibodies in biosensor applications. Incorporating aptamers enables the flexible sensor to deliver accurate and ongoing monitoring capabilities, converting cytokine binding into quantifiable electrical signals. The device’s features render it especially effective for monitoring dynamic fluctuations in inflammatory biomarkers. This study presents the benchtop validation of a novel aptamer-based sensor designed to detect CRP in phosphate buffer solution (PBS) and human sweat. The dynamic range of CRP was established between 0.5 and 8.0 ng/mL, exhibiting a sensitivity of 0.22 ng/mL, while the limit of quantification (LOQ) was determined to be 0.65 ng/mL. Studies on cocktails have confirmed that the sensor showed no significant interference from biomarkers such as TNF-α, IL6, and IL8 for the CRP sensor. The evaluation of the flexible sensor demonstrated its capability to detect biomarkers in human sweat samples with impressive accuracy in approximately 3 min of incubation. The limits of detection and quantification were 1.20 ng/mL and 3.60 ng/mL, respectively. The sensing mechanism of the flexible sensor indicates that the interaction between the biomarker and the aptamer on the electrode surface modifies the electrical characteristics of the interface. This alteration generally results in a more conductive pathway, attributed to conformational changes in the aptamer, which facilitate an increased transfer of electrons between the electrode and the solution, ultimately resulting in a reduced impedance reading. Graphical AbstractKeywords
Funding Information
- EnLiSense LLC/Crohn’s & Colitis Sponsor Award (1034125)
This publication has 52 references indexed in Scilit:
- Handbook of Material Engineering in Nanobiomedicine and Diagnostics2025
- PathoSense: a rapid electroanalytical device platform for screening Salmonella in water samplesMicrochimica Acta, 2024
- Passive sweat wearable: A new paradigm in the wearable landscape toward enabling “detect to treat” opportunitiesWIREs Nanomedicine and Nanobiotechnology, 2023
- Novel Approach to Track the Lifecycle of Inflammation from Chemokine Expression to Inflammatory Proteins in Sweat Using Electrochemical BiosensorAdvanced Materials Technologies, 2022
- Temporal profiling of cytokines in passively expressed sweat for detection of infection using wearable deviceBioengineering & Translational Medicine, 2021
- Saliva as an emerging biofluid for clinical diagnosis and applications of MEMS/NEMS in salivary diagnostics2019
- Electrical double layer modulation of hybrid room temperature ionic liquid/aqueous buffer interface for enhanced sweat based biosensingAnalytica Chimica Acta, 2018
- Electrochemical Biosensors in Point‐of‐Care Devices: Recent Advances and Future TrendsChemElectroChem, 2017
- C-reactive protein and the biology of diseaseImmunologic Research, 2013
- An immunoturbidimetric assay for canine C-reactive proteinVeterinary Research Communications, 1991