MR Imaging Artifacts and Parallel Imaging Techniques with Calibration Scanning: A New Twist on Old Problems
Authors:
- Michael J. KellyMKMichael J. Kelly
- 1 March 2014
- journal article
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 34 (2) , 532-548
Abstract
The application of parallel magnetic resonance (MR) imaging is increasing as clinicians continue to strive for improved spatial and temporal resolution, benefits that arise from the use of fewer phase encodings during imaging. To reconstruct images, extra information is needed to map the spatial sensitivity of each coil element, which may be accomplished by acquiring a calibration image in one common implementation of parallel MR imaging. Although obtaining a quick calibration image is an efficient method for gathering this information, corruption of the image or disharmony with subsequent images may lead to errors in reconstruction. Although conventional MR imaging sequences may be employed with parallel MR imaging, the altered image reconstruction introduces several new artifacts and changes the appearance of conventional artifacts. The altered appearance of traditional artifacts may obscure the source of the problem, and, in some cases, the severity of artifacts associated with parallel MR imaging may be exacerbated, hindering image interpretation. Several artifacts arise in the context of parallel MR imaging, including both traditional artifacts and those associated with parallel MR imaging.Keywords
This publication has 15 references indexed in Scilit:
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- Parallel Imaging Artifacts in Body Magnetic Resonance ImagingCanadian Association of Radiologists Journal, 2009
- From A as in Aliasing to Z as in Zipper: Artifacts in MRIClinical Neuroradiology, 2008
- Accelerated volumetric MRI with a SENSE/GRAPPA combinationJournal of Magnetic Resonance Imaging, 2006
- The SENSE ghost: Field‐of‐view restrictions for SENSE imagingJournal of Magnetic Resonance Imaging, 2004
- Field‐of‐view limitations in parallel imagingMagnetic Resonance in Medicine, 2004
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP)Magnetic Resonance in Medicine, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997