3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation
- 1 February 2004
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 14 (2) , 326-333
Abstract
The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110±180 ml for right lobes, 820 ml for the left lobe and 270±30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments.Keywords
This publication has 15 references indexed in Scilit:
- Analysis of vasculature for liver surgical planningIEEE Transactions on Medical Imaging, 2002
- Potential Living Liver Donors: Evaluation with an All-in-One Protocol with Multi–Detector Row CTRadiology, 2002
- Use of multidetector row CT with volume renderings in right lobe living liver transplantationEuropean Radiology, 2002
- Accuracy of Volumetric Measurements After Virtual Right Hepatectomy in Potential Donors Undergoing Living Adult Liver TransplantationAmerican Journal of Roentgenology, 2001
- The Impact of 3-Dimensional Reconstructions on Operation Planning in Liver SurgeryArchives of Surgery, 2000
- ACCURACY AND SIGNIFICANCE OF COMPUTED TOMOGRAPHIC SCAN ASSESSMENT OF HEPATIC VOLUME IN PATIENTS UNDERGOING LIVER TRANSPLANTATIONTransplantation, 2000
- IMPACT OF GRAFT SIZE MISMATCHING ON GRAFT PROGNOSIS IN LIVER TRANSPLANTATION FROM LIVING DONORS1,2Transplantation, 1999
- Automatic liver segmentation technique for three-dimensional visualization of CT data.Radiology, 1996
- Functional Analysis of Grafts from Living DonorsAnnals of Surgery, 1996
- In vivo hepatic volume determination using sonography and computed tomographyGastroenterology, 1985