In-situ measurement of Poisson's ratio for germanium nano-bridge in TEM
- 1 May 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
In the work a microelectromechanical systems (MEMS) based in-situ tensile test for germanium nano-bridge in transmission electron microscope is presented. With a carefully designed electrostatic actuator, germanium nano-bridge can be stretched stably at a speed rate less than 0.05% per step in strain. Assisted with the selected area electron diffraction (SAED) images, Poisson's ratios measured from a local area whose diameter is less than 20 nm can be obtained. Three different sized samples (marked as a, b, c) were tested and the Poisson's ratios were measured to be 0.18, 0.25, 0.27, respectively, comparing to 0.28 for the bulk germanium. The smallest scaled sample (a) presents a remarkable lower Poisson's ratio than bulk germanium, which may result from the increasing radial stress caused by the decreasing dimension of the nano-bridge.Keywords
This publication has 10 references indexed in Scilit:
- Individual nanowire handling for NEMS fabrication2012
- Academic and industry research progress in germanium nanodevicesNature, 2011
- Approaching the Theoretical Elastic Strain Limit in Copper NanowiresNano Letters, 2011
- Diameter-Dependent Radial and Tangential Elastic Moduli of ZnO NanowiresNano Letters, 2007
- Size Dependence of Young’s Modulus in ZnO NanowiresPhysical Review Letters, 2006
- Growth of nanowire superlattice structures for nanoscale photonics and electronicsNature, 2002
- Room-Temperature Ultraviolet Nanowire NanolasersScience, 2001
- Evaluation of size effect on mechanical properties of single crystal silicon by nanoscale bending test using AFMJournal of Microelectromechanical Systems, 2000
- Young's Modulus, Shear Modulus, and Poisson's Ratio in Silicon and GermaniumJournal of Applied Physics, 1965
- Elasticity and Thermal Expansion of Germanium Between −195 and 275°CJournal of Applied Physics, 1953