Reducing costs in flow-cytometric counting of residual white blood cells in blood products: utilization of a single-platform bead-free flow-rate calibration method
- 7 January 2011
- journal article
- Published by Wiley in Transfusion
- Vol. 51 (7) , 1431-1438
Abstract
Commercial flow-cytometric methods for counting residual white blood cells (rWBCs) in leukoreduced blood products use calibration beads for estimation of the measured sample volume. A bead-free flow-rate calibration method is developed and validated. The analyzed volume was calculated by acquisition time (ACQ). Twenty-nine spiking series of red blood cell (RBC) or platelet (PLT) products were prepared containing levels ranging from 0.08 × 10(6) up to 2048 × 10(6) WBCs/L. Nearly WBC-free triple-leukofiltered RBCs or PLT concentrates (PCs) served as background. Propidium iodide (PI) was used to identify rWBCs. Five RBC series were compared against a commercially available kit (LeukoSure, Beckman Coulter). Routine capabilities were tested on 41 RBC and 92 PC samples of two independent transfusion services. The lower detection limit in RBC was 0.08 × 10(6) rWBCs/L for ACQ and 0.16 for LeukoSure. Criteria for linearity, accuracy, and precision were fulfilled within the range of 0.5 × 10(6) to 512 × 10(6) WBCs/L. For PCs, all these criteria were fulfilled between 0.5 × 10(6) and 32 × 10(6) rWBCs/L (lower detection limit of 0.25) for PI. ACQ and LeukoSure agreed sufficiently (81%) when tested on routine RBCs or PCs. A residual WBC count of fewer than 0.5 × 10(6) WBCs/L can be accurately counted using the ACQ approach at a total reagent cost of less than 0.5€ per sample.Keywords
This publication has 31 references indexed in Scilit:
- Flow rate calibration. III. The use of stabilized biostandards to calibrate the flow rate and calculate absolute CD4+ T-cell countsCytometry Part B: Clinical Cytometry, 2006
- Review of the quality monitoring methods used by countries using or implementing universal leukoreductionTransfusion Medicine Reviews, 2004
- Flow rate calibration II: A clinical evaluation study using PanLeucoGating as a single-platform protocolCytometry, 2003
- Stability of currently used cytometers facilitates the identification of pipetting errors and their volumetric operation: ?Time? can tell allCytometry, 2003
- Principles of counting low numbers of leukocytes in leukoreduced blood componentsTransfusion Medicine Reviews, 1997
- Standardization of absolute CD4+ lymphocyte counts across laboratories: An evaluation of the ortho CytoronAbsolute flow cytometry system on normal donorsCytometry, 1995
- Clinical significance of white cell antibodies in febrile nonhemolytic transfusion reactionsTransfusion, 1990
- Flow‐Cytometric Method for Counting Very Low Numbers of Leukocytes in Platelet Products1Vox Sanguinis, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Alloimmunisation to HLA Antigens following Transfusion with Leucocyte‐Poor and Purified Platelet SuspensionsVox Sanguinis, 1985