Abstract
Shear-wave imaging optical coherence elastography (SWI-OCE) is an emerging method for 3D quantitative assessment of tissue local mechanical properties based on imaging and analysis of elastic wave propagation. Current methods for SWI-OCE involve multiple temporal optical coherence tomography scans (M-mode) at different spatial locations across tissue surface (B- and C-modes). This requires an excitation for each measurement position leading to clinically unacceptable long acquisition times up to tens of minutes. In this Letter, we demonstrate, for the first time, noncontact true kilohertz frame-rate OCE by combining a Fourier domain mode-locked swept source laser with an A-scan rate of and a focused air-pulse as an elastic wave excitation source. The propagation of the elastic wave in the sample was imaged at a frame rate of . Therefore, to quantify the elastic wave propagation velocity in a single direction, only a single excitation was needed. This method was validated by quantifying the elasticity of tissue-mimicking agar phantoms as well as of a porcine cornea ex vivo at different intraocular pressures. The results demonstrate that this method can reduce the acquisition time of an elastogram to milliseconds.
Keywords
Funding Information
- National Institutes of Health (NIH) (1R01EY022362, 1R01HL120140, U54HG006348)
- Naval Sea Systems Command (NAVSEA) (PRJ71TN)
This publication has 34 references indexed in Scilit:
- Real-time 4D signal processing and visualization using graphics processing unit on a regular nonlinear-k Fourier-domain OCT systemOptics Express, 2010
- Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomographyOptics Express, 2006
- Thyroid Gland Tumor Diagnosis at US ElastographyRadiology, 2005
- Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasoundJACC, 2002
- Association Between Arterial Stiffness and AtherosclerosisStroke, 2001
- Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain WavesScience, 1995
- Quantitative Assessment of Macular Edema With Optical Coherence TomographyArchives of Ophthalmology (1950), 1995
- Optical Coherence TomographyScience, 1991
- Elastography: A Quantitative Method for Imaging the Elasticity of Biological TissuesUltrasonic Imaging, 1991
- Comparison of mechanical properties of keratoconus and normal corneasExperimental Eye Research, 1982