Long-term outcomes of a rapid deployment aortic valve: data up to 5 years†
- 26 April 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 52 (2) , 281-287
Abstract
OBJECTIVES: Rapid deployment aortic valve replacement (AVR) has been developed to facilitate minimally invasive approaches for cardiac surgery and shorten procedural times. TRITON is a prospectively designed study to assess safety and efficacy of rapid deployment AVR with Edwards INTUITY valve system. This report presents the 5-year outcomes of the TRITON trial. METHODS: A total of 295 patients with aortic valve stenosis were enrolled in the TRITON trial and 287 patients received the study valve. Procedural, early (≤30 days) and late (>30 days) outcomes were collected. Valve haemodynamic performance was evaluated at specified time points by an independent Echocardiography Core Laboratory and clinical events adjudicated by an independent Clinical Events Committee. RESULTS: Mean age was 75.3 ± 6.7 years. A total of 158 patients underwent isolated AVR and 129 patients underwent AVR with concomitant procedures. The 5-year survival rates were 85.7 ± 3.4% and 75.2 ± 4.9% for isolated AVR and concomitant AVR, respectively. Overall, freedom from valve-related death at 5 years was 98.2 ± 0.8%. At 5 years, the valve effective orifice area was 1.6 ± 0.3 cm2, mean gradient was 10.5 ± 5.4 mmHg and peak gradient was 18.9 ± 9.3 mmHg. CONCLUSIONS: The 5-year outcomes of the TRITON trial demonstrate acceptable long-term safety and excellent haemodynamic performance of rapid deployment AVR with the Edwards INTUITY valve system. ClinicalTrials.gov: NCT01445171.Keywords
This publication has 23 references indexed in Scilit:
- Early outcomes after isolated aortic valve replacement with rapid deployment aortic valveThe Journal of Thoracic and Cardiovascular Surgery, 2016
- Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trialEuropean Journal of Cardio-Thoracic Surgery, 2016
- Three-year hemodynamic performance, left ventricular mass regression, and prosthetic-patient mismatch after rapid deployment aortic valve replacement in 287 patientsThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Clinical performance of a sutureless aortic bioprosthesis: Five-year results of the 3f Enable long-term follow-up studyThe Journal of Thoracic and Cardiovascular Surgery, 2014
- One-year outcomes of the Surgical Treatment of Aortic Stenosis With a Next Generation Surgical Aortic Valve (TRITON) trial: A prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve SystemThe Journal of Thoracic and Cardiovascular Surgery, 2013
- Guidelines on the management of valvular heart disease (version 2012)European Journal of Cardio-Thoracic Surgery, 2012
- Sutureless Perceval Aortic Valve Replacement: Results of Two European CentersThe Annals of Thoracic Surgery, 2012
- Guidelines for the Evaluation of Prosthetic Valves with Echocardiography and Doppler Ultrasound: Value and LimitationsEchocardiography, 2010
- Ministernotomy versus conventional sternotomy for aortic valve replacement: A systematic review and meta-analysisThe Journal of Thoracic and Cardiovascular Surgery, 2009
- Guidelines for Reporting Mortality and Morbidity After Cardiac Valve InterventionsThe Annals of Thoracic Surgery, 2008