Evaluation of iris recognition system for wavefront-guided laser in situ keratomileusis for myopic astigmatism
Authors:
- Hugh R. TaylorHTHugh R. Taylor
- Rasik B. VajpayeeRVRasik B. Vajpayee
- 1 February 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (2) , 215-221
Abstract
To evaluate the visual and refractive outcomes of wavefront-guided laser in situ keratomileusis (LASIK) using an iris recognition system for the correction of myopic astigmatism. Centre for Eye Research Australia, Melbourne Excimer Laser Research Group, and Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia. A comparative analysis of wavefront-guided LASIK was performed with an iris recognition system (iris recognition group) and without iris recognition (control group). The main parameters were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, amount of residual cylinder, manifest spherical equivalent (SE), and the index of success using the Alpins method of astigmatism analysis 1 and 3 months postoperatively. A P value less than 0.05 was considered statistically significant. Preoperatively, the mean SE was -4.32 diopters (D) +/- 1.59 (SD) in the iris recognition group (100 eyes) and -4.55 +/- 1.87 D in the control group (98 eyes) (P = .84). At 3 months, the mean SE was -0.05 +/- 0.21 D and -0.20 +/- 0.40 D, respectively (P = .001), and an SE within +/-0.50 D of emmetropia was achieved in 92.0% and 85.7% of eyes, respectively (P = .07). At 3 months, the UCVA was 20/20 or better in 90.0% and 76.5% of eyes, respectively. A statistically significant difference in the amount of astigmatic correction was seen between the 2 groups (P = .00 and P = .01 at 1 and 3 months, respectively). The index of success was 98.0% in the iris recognition group and 81.6% in the control group (P = .03). Iris recognition software may achieve better visual and refractive outcomes in wavefront-guided LASIK for myopic astigmatism.Keywords
This publication has 24 references indexed in Scilit:
- Eleven-year follow-up of laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2007
- Laser in situ keratomileusis flap thickness using the Hansatome microkeratome with zero compression headsJournal of Cataract & Refractive Surgery, 2006
- Iris-Based Cyclotorsional Image Alignment Method for Wavefront RegistrationIEEE Transactions on Biomedical Engineering, 2005
- Wavefront-guided LASIK with the Zyoptix 3.1 system for the correction of myopia and compound myopic astigmatism with 1-year follow-upOphthalmology, 2004
- Zyoptix: the Bausch & Lomb wavefront platformOphthalmology Clinics of North America, 2004
- Cyclotorsional eye motion occurring between wavefront measurement and refractive surgeryJournal of Cataract & Refractive Surgery, 2004
- Wavefront- and topography-guided ablation in myopic eyes using ZyoptixJournal of Cataract & Refractive Surgery, 2004
- Clinical outcomes of wavefront-guided laser in situ keratomileusis: 6-month follow-upJournal of Cataract & Refractive Surgery, 2003
- Cyclotorsion in the seated and supine patientJournal of Cataract & Refractive Surgery, 1995
- Astigmatic Excimer Laser Treatment: Theoretical Effects of Axis MisalignmentEuropean journal of Implant and Refractive Surgery, 1994