Investigation of the Startup Condition of a Closed-Loop Oscillating Heat Pipe
Authors:
- 1 July 2009
- journal article
- research article
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 30 (8) , 626-642
Abstract
This article develops a concept for a suitable startup condition for a closed-loop oscillating heat pipe (CLOHP). This concept was developed by using visual data and the thermodynamics theory for predicting the amount of vapor evaporation and condensation in a CLOHP. The visual data indicated that the key to a suitable startup is the amount of net vapor expansion in the evaporator and the amount of net collapsed vapor in the condenser. Initial dryout, an event that occurs after a startup failure, results when the net vapor expansion is higher than the amount of net vapor collapsed. This situation obstructs the replacement process. This is a mechanism in which the volume of mixture from the condenser section flows to the evaporator section to replace the volume of mixture that leaves the evaporator section. When the replacement process is impeded, all of the liquid in the evaporator section evaporates and the evaporator section is not refilled by the mixture from the condenser section. The evaporator section is then filled with vapor and initial dryout occurs. In addition, this article presents a mathematical model that predicts the operating temperature for a suitable startup condition. This prediction can be used to avoid a startup failure of a CLOHP. When comparing the model with that of the experimental data, a 16% error range was attained.Keywords
This publication has 8 references indexed in Scilit:
- Theoretical analysis of startup of a pulsating heat pipeInternational Journal of Heat and Mass Transfer, 2007
- An experimental study on an oscillating loop heat pipe consisting of three interconnected columnsHeat and Mass Transfer, 2006
- High speed flow visualization of a closed loop pulsating heat pipeInternational Journal of Heat and Mass Transfer, 2005
- Operation modeling of closed-end and closed-loop oscillating heat pipes at normal operating conditionApplied Thermal Engineering, 2004
- Theoretical and experimental modelling of an open oscillatory heat pipe including gravityInternational Journal of Thermal Sciences, 2004
- Closed loop pulsating heat pipesApplied Thermal Engineering, 2003
- Closed loop pulsating heat pipes Part B: visualization and semi-empirical modelingApplied Thermal Engineering, 2003
- Experimental investigation of oscillating heat pipes2002