Expandable Polyaryl-Ether-Ether-Ketone Spacers for Interbody Distraction in the Lumbar Spine
Authors:
Open Access
- 18 June 2015
- journal article
- Published by SAGE Publications in Global Spine Journal
- Vol. 5 (3) , 169-178
Abstract
Study Design: Retrospective case series. Objective: StaXx XD (Spine Wave, Inc., Shelton, CT, United States) is an expandable polyaryl-ether-ether-ketone (PEEK) wafer implant utilized in the treatment of lumbar degenerative disease. PEEK implants have been successfully used as interbody devices. Few studies have focused on expandable PEEK devices. The aim of the current study is to determine the radiographic and clinical outcome of expandable PEEK cages utilized for transforaminal lumbar interbody fusion in patients with lumbar degenerative diseases. Methods: Forty-nine patients who underwent lumbar interbody fusion with implantation of expandable PEEK cages and posterior instrumentation were included. The clinical outcome was evaluated using the visual analog scale (VAS) and the Oswestry Disability Index (ODI). Radiographic parameters including disk height, foraminal height, listhesis, local disk angle of the index level/levels, regional lumbar lordosis, and graft subsidence were measured preoperatively, postoperatively, and at latest follow-up. Results: At an average follow-up of 19.3 months, the minimum clinically important difference for the ODI and VAS back, buttock, and leg were achieved in 64, 52, 58, and 52% of the patients, respectively. There was statistically significant improvement in VAS back (6.42 versus 3.11, p < 0.001), VAS buttock (4.66 versus 1.97, p = 0.002), VAS leg (4.55 versus 1.96, p < 0.001), and ODI (21.7 versus 12.1, p < 0.001) scores. There was a significant increase in the average disk height (6.49 versus 8.18 mm, p = 0.037) and foraminal height (15.6 versus 18.53 mm, p = 0.0001), and a significant reduction in the listhesis (5.13 versus 3.15 mm, p = 0.005). The subsidence of 0.66 mm (7.4%) observed at the latest follow-up was not significant ( p = 0.35). Conclusions: Midterm results indicate that expandable PEEK spacers can effectively and durably restore disk and foraminal height and improve the outcome without significant subsidence.Keywords
This publication has 19 references indexed in Scilit:
- PEEK biomaterials in trauma, orthopedic, and spinal implantsBiomaterials, 2007
- Minimally invasive transforaminal lumbar interbody fusion: indications, technique, and complicationsNeurosurgical Focus, 2006
- Polyetheretherketone as a biomaterial for spinal applicationsBiomaterials, 2006
- Intervertebral cages for degenerative spinal diseasesThe Spine Journal, 2003
- The clinical importance of changes in outcome scores after treatment for chronic low back painEuropean Spine Journal, 2003
- The Use of Interbody Cage Devices for Spinal Deformity: A Biomechanical PerspectiveClinical Orthopaedics and Related Research, 2002
- Clinical importance of changes in chronic pain intensity measured on an 11-point numerical pain rating scalePain, 2001
- A Comparison of a Modified Oswestry Low Back Pain Disability Questionnaire and the Quebec Back Pain Disability ScalePhysical Therapy, 2001
- Defining the clinically important difference in pain outcome measuresPain, 2000
- Measuring the Functional Status of Patients With Low Back PainSpine, 1995