Buoyant wind-driven pollutant dispersion and recirculation behaviour in wedge-shaped roof urban street canyons
Authors:
- 31 January 2019
- journal article
- research article
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 26 (8) , 8289-8302
Abstract
The present study investigated the buoyant wind-driven pollutant plume dispersion and recirculation behaviour inside urban street canyons formed by buildings with wedge-shaped roofs. Numerical modelling was performed using a computational fluid dynamics (CFD) large eddy simulation (LES). Street canyon models with a strongly buoyant fire source located on the street and environmental winds perpendicular to the canyon were developed using the fire dynamics simulator (FDS). The complex interaction of buoyancy and wind, as well as their combined effects on the pollutant plume dispersion, was simulated inside the urban street canyon. The results showed that the flow pattern of pollutant plume dispersion inside the street canyon with increasing wind speed for different roof inclination angles could be divided into three regimes, including a recirculation regime, a quasi-recirculation regime and a non-recirculation regime. The pollutant levels in the street canyon, as indexed by carbon monoxide (CO) concentration, increased under the recirculation regime. For the quasi-recirculation regime, however, the leeward buildings primarily suffered from the higher pollutant levels. The critical wind speed needed to trigger recirculation was analysed for various roof inclination angles. A correlation was proposed to predict the critical wind speed of various wedge-shaped roof angles for recirculation regime and quasi-recirculation regimes.Keywords
This publication has 26 references indexed in Scilit:
- A review of physics and correlations of pool fire behaviour in wind and future challengesFire Safety Journal, 2017
- A GLOBAL RELATION OF FIRE SMOKE RE-CIRCULATION BEHAVIOUR IN URBAN STREET CANYONSJOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2015
- Exploring the processes governing roadside pollutant concentrations in urban street canyonEnvironmental Science and Pollution Research, 2013
- NUMERICAL STUDIES ON SMOKE SPREAD IN THE CAVITY OF A DOUBLE-SKIN FAÇADE / SKAITINIS DŪMŲ SKLIDIMO DVIGUBO FASADO ERTMĖJE TYRIMASJOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2011
- Large eddy simulation of pollutant gas dispersion with buoyancy ejected from building into an urban street canyonJournal of Hazardous Materials, 2011
- Large eddy simulation of fire-induced buoyancy driven plume dispersion in an urban street canyon under perpendicular wind flowJournal of Hazardous Materials, 2009
- FIRE SAFETY ASPECTS OF REFUGE FLOORS IN SUPERTALL BUILDINGS WITH COMPUTATIONAL FLUID DYNAMICSJOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2009
- Studies on buoyancy-driven back-layering flow in tunnel firesExperimental Thermal and Fluid Science, 2008
- Computational Fluid Dynamics Simulation of Concentration Distributions from a Point Source in the Urban Street CanyonsJournal of Aerospace Engineering, 2006
- A study of the dispersion and transport of reactive pollutants in and above street canyons—a large eddy simulationAtmospheric Environment, 2004