Human Gait Estimation Using Multiple 2D LiDARs
Open Access
- 5 April 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 56881-56892
Abstract
This paper proposes a human gait estimation algorithm using a multiple 360 degree 2D LiDARs system. The system is fixed on the ground at the shin height to scan human legs during gait. The multiple LiDARs system is to overcome the drawbacks of a single LiDAR system, which could lose data due to occlusion between legs during walking and has a short tracking range. The performance of a sensor fusion system strongly depends on the calibration. In this paper, we propose a calibration method using a cylinder with known radius as a specific marker. In contrast to other methods, the calibration parameters and the cylinder center points at different positions are estimated by a proposed iterative algorithm. The measurement noises in the LiDAR output are considered to increase the accuracy of calibration and human leg center points estimation. Instead of using least square fitting of circle algorithm to estimate the leg center point, a new iterative algorithm which includes measurement noises is proposed. Although multiple LiDARs are used, the discontinuities of leg center points could still happen. Therefore, a quadratic optimization based eighth-order splines algorithm is derived to interpolate and smooth the data. Two configurations of three LiDARs are tested in the experiment. The former is the triangle configuration in which the whole walking path is covered by all three LiDARs. This configuration minimizes the occlusion between legs. The maximum RMSE of step length estimation of this configuration compared with the optical camera system is 0.03m. The latter is the line configuration in which each LiDAR covers a certain walking path sequentially. This configuration maximizes the tracking range. The experiment with 20m straight walking has the RMSE of about 0.10m.Keywords
Funding Information
- 2020 Research Fund of University of Ulsan
This publication has 30 references indexed in Scilit:
- Extrinsic Calibration of 2-D Lidars Using Two Orthogonal PlanesIEEE Transactions on Robotics, 2015
- Improved Leg Tracking Considering Gait Phase and Spline-Based Interpolation during Turning Motion in Walk TestsSensors, 2015
- Frontal Gait Recognition From Incomplete Sequences Using RGB-D CameraIEEE Transactions on Information Forensics and Security, 2014
- IMU-Based Joint Angle Measurement for Gait AnalysisSensors, 2014
- Validation of a protocol for the estimation of three-dimensional body center of mass kinematics in sportGait & Posture, 2014
- Personal Navigation via High-Resolution Gait-Corrected Inertial Measurement UnitsIEEE Transactions on Instrumentation and Measurement, 2010
- Measuring Gait Using a Ground Laser Range SensorSensors, 2009
- A collection of outdoor robotic datasets with centimeter-accuracy ground truthAutonomous Robots, 2009
- Reliability of the GAITRite® walkway system for the quantification of temporo-spatial parameters of gait in young and older peopleGait & Posture, 2004
- Data Smoothing and Interpolation Using Eighth-order Algebraic SplinesIEEE Transactions on Signal Processing, 2004