Charge injection characteristics of sputtered ruthenium oxide electrodes for neural stimulation and recording
Authors:
- 14 July 2021
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 110 (1) , 229-238
Abstract
We have studied the charge‐injection characteristics and electrochemical impedance of sputtered ruthenium oxide (RuOx) films as electrode coatings for neural stimulation and recording electrodes. RuOx films were deposited by reactive DC magnetron sputtering, using a combination of water vapor and oxygen gas as reactive plasma constituents. The cathodal charge storage capacity of planar RuOx electrodes was found to be 54.6 ± 9.5 mC/cm2 (mean ± SD, n = 12), and the charge‐injection capacity in a 0.2‐ms cathodal current pulse was found to be 7.1 ± 0.3 mC/cm2 (mean ± SD, n = 15) at 0.6 V positive bias versus Ag|AgCl, in phosphate buffer saline at room temperature for ~250 nm thick films. In general, the RuOx films exhibited high charge‐injection capacities, with or without a positive interpulse bias, comparable to sputtered iridium oxide (SIROF) coatings. The charge‐injection capacity increased monotonically with film thickness from 120 to 630 nm, and reached 11.30 ± 0.34 mC/cm2 (mean ± SD, n = 5) at 0.6 V bias versus Ag|AgCl at 630 nm film thickness. In addition, RuOx films showed minimal changes in electrochemical characteristics over 1.5 billion cycles of constant current pulsing at a charge density of 408 μC/cm2 (8 nC/phase, 200 μs pulse width). The findings of low‐impedance, high charge‐injection capacity, and long‐term pulsing stability suggest the suitability of RuOx as a comparatively inexpensive and favorable choice of electrode material for neural stimulation and recording.Keywords
Funding Information
- National Institutes of Health (5R01NS104344‐02)
This publication has 43 references indexed in Scilit:
- Proprioceptive and cutaneous sensations in humans elicited by intracortical microstimulationeLife, 2018
- Toward a Proprioceptive Neural Interface that Mimics Natural Cortical Activity2016
- Intracortical microstimulation of human somatosensory cortexScience Translational Medicine, 2016
- In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arraysBiomedical Materials, 2010
- Neural Stimulation and Recording ElectrodesAnnual Review of Biomedical Engineering, 2008
- Direct neural sensory feedback and control of a prosthetic armIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- Visuotopic Mapping Through a Multichannel Stimulating Implant in Primate V1Journal of Neurophysiology, 2005
- Electrical stimulation of excitable tissue: design of efficacious and safe protocolsJournal of Neuroscience Methods, 2005
- Visual perception in a blind subject with a chronic microelectronic retinal prosthesisVision Research, 2003
- Electrical stimulation with Pt electrodes. VIII. Electrochemically safe charge injection limits with 0.2 ms pulses (neuronal application)IEEE Transactions on Biomedical Engineering, 1990