Reflectance of the Women Skin from the Ultraviolet to the Far-Infrared Spectrum Across Different Body Regions at Incidence Angles of 20° and 60°
Open Access
- 13 May 2026
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 16 (10) , 4877
Abstract
Background: Directional hemispherical reflectance (DHR) is a precise method for evaluating skin reflectance and is widely used in dermatological, photobiological, and cosmetic or pharmaceutical research. Reflectance measurements may support emissivity-related interpretation, particularly in the infrared range, being influenced by chromophore content, epidermal structure, and physiological factors such as hydration, pigmentation, and surface heterogeneity. However, most in vivo studies have focused on limited spectral ranges or selected anatomical sites. This study aimed to assess skin directional hemispherical reflectance across a broad spectral range and to provide an integrated dataset supporting emissivity-related interpretation in the infrared region. Methods: The study included 20 women aged 22–50 years (27 ± 9 years) with Fitzpatrick skin phototypes II–III. Reflectance measurements were performed at 14 anatomical sites using an ET 100 emissometer (1.9–21 µm) and an SOC 410 Solar DHR reflectometer (335–2500 nm). Infrared measurements were conducted at incidence angles of 20° and 60° to assess angular effects. Data were statistically analyzed. Results: The lowest reflectance values were observed within 335–380 nm, 1700–2500 nm, and 1.5–21 µm, whereas the highest reflectance was recorded in the 590–720 nm and 700–1100 nm bands. Reflectance symmetry between body sides was observed. In the infrared range, reflectance decreased with increasing wavelength, while mid- and far-infrared values were more uniform across locations. The highest reflectance values were noted for the thigh, calf (crural region), forearm, and palmar surface of the hand, whereas the lowest values were observed in the neck, abdominal region, and dorsal surface of the hand. Measurements at 60° incidence yielded higher reflectance values than those at 20°, while preserving spatial patterns. Conclusions: Directional hemispherical reflectance provides a robust approach for assessing skin reflectance across a broad spectral range. Reflectance depends on wavelength, anatomical location, and physiological factors, including epidermal thickness, pigmentation, and sebum presence. The integrated analysis of spectral, anatomical, and angular variability may support improved interpretation of skin optical properties and contribute to reference data for biomedical and infrared imaging applications.Keywords
Funding Information
- Medical University of Silesia in Katowice (BNW-1-108/K/4/I)
This publication has 30 references indexed in Scilit:
- Non-ablative laser skin rejuvenation by targeting indigenous chromophoresJournal of King Saud University – Science, 2024
- Updates on Lasers in DermatologyDermatologic Clinics, 2023
- Comparative analysis of the methods for quantitative determination of water content in skin from diffuse reflectance spectroscopy dataQuantum Electronics, 2020
- The Use of Directional Reflectance Measurement for in vivo Assessment of Protective Properties of Cosmetics in the Infrared Radiation RangePhotochemistry and Photobiology, 2017
- Enhanced thermal imaging of wound tissue for better clinical decision makingPhysiological Measurement, 2017
- Metal oxide sunscreens protect skin by absorption, not by reflection or scatteringPhotodermatology, Photoimmunology & Photomedicine, 2015
- Classification of factors influencing the use of infrared thermography in humans: A reviewInfrared Physics & Technology, 2015
- Investigating skin barrier function utilizing reflectance NIR Spectroscopy2014
- Infrared camera assessment of skin surface temperature – Effect of emissivityPhysica Medica, 2013
- Retrieving skin properties fromin vivospectral reflectance measurementsJournal of Biophotonics, 2011