Entrance surface doses to patients undergoing selected diagnostic X-ray examinations in Sudan
Authors:
- I. I. SulimanISI. I. Suliman
- N. AbbasNAN. Abbas
- F. I. HabbaniFHF. I. Habbani
- 14 September 2006
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 123 (2) , 209-214
Abstract
The aim of the study was to evaluate the entrance surface doses (ESDs) to patients undergoing selected diagnostic X-ray examinations in major Sudanese hospitals. ESD per examination was estimated from X-ray tube output parameters in four hospitals comprising eight X-ray units and a sample of 346 radiographs. Hospital mean ESDs estimated range from 0.17 to 0.27 mGy for chest AP, 1.04–2.26 mGy for Skull AP/PA, 0.83–1.32 mGy for Skull LAT, 1.31–1.89 mGy for Pelvis AP, 1.46–3.33 mGy for Lumbar Spine AP and 2.9–9.9 mGy for Lumbar Spine LAT. With exception of chest PA examination at two hospitals, mean ESDs were found to be within the established international reference doses. The results are useful to national and professional organisations and can be used as a baseline upon which future dose measurements may be compared.Keywords
This publication has 11 references indexed in Scilit:
- Dose evaluation for paediatric chest x-ray examinations in Brazil and Sudan: low doses and reliable examinations can be achieved in developing countriesPhysics in Medicine & Biology, 2004
- The effect of beam tube potential variation on gonad dose to patients during chest radiography investigated using high sensitivity LiF:Mg,Cu,P thermoluminescent dosemetersBritish Journal of Radiology, 2001
- Patient Dosimetry Protocols in Digital and Interventional RadiologyRadiation Protection Dosimetry, 2001
- The AAPM/RSNA Physics Tutorial for ResidentsRadioGraphics, 1999
- Increasing FFD: An effective dose-reducing tool for lateral lumbar spine investigationsRadiography, 1998
- Dose reduction in a paediatric X-ray department following optimization of radiographic technique.British Journal of Radiology, 1998
- Analysis of Dose and Dose Distribution for Patients Undergoing Selected X-Ray Diagnostic Procedures in GhanaRadiation Protection Dosimetry, 1998
- Image quality and dose in lumbar spine examinations: results of a 5 year quality control programme following the European quality criteria trialBritish Journal of Radiology, 1995
- The significance of patient weight when comparing X-ray room performance against guideline levels of doseBritish Journal of Radiology, 1991
- Quantities used in radiological protectionAnnals of the ICRP, 1991