Design of refractive index sensing based on optimum combination of plasmonic materials gold with indium tin oxide/titanium dioxide
- 1 April 2022
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Nanophotonics
- Vol. 16 (02) , 026010-19
Abstract
In this research work, a penta core photonic crystal fiber (PCF)-based refractive index (RI) sensor is presented to address the surface plasmon resonance (SPR) phenomenon. The proposed RI sensor (PRIS) model is tested with two material configurations, i.e., gold-indium tin oxide (Au–ITO) and gold–titanium dioxide (Au–TiO2). Analytes having an RI varying from 1.340 to 1.380 RIU are tested from the PRIS for both material configurations. These configurations are compared with each other based on sensor parameters, such as wavelength sensitivity (WS), amplitude sensitivity (AS), linearity, and sensor resolution (SR). The sensor parameters are investigated for both transverse electric (TM) mode and transverse electric (TE) mode. The proposed sensor with Au–ITO configuration offers a maximum WS of 12,000 nm / RIU, AS of 13,640 RIU − 1, and maximum SR of 8.33 × 10 − 6 RIU for TM mode. Corresponding to the TE mode maximum WS of 11,000 nm / RIU, AS of 12,180 RIU − 1 and maximum SR of 9.09 × 10 − 6 RIU are obtained. The proposed sensor with the Au–TiO2 configuration presents a maximum WS of 12,000 nm / RIU, AS of 20,370 RIU − 1, and maximum SR of 8.33 × 10 − 6 RIU for the TM mode. Corresponding to the TE mode maximum WS of 13,000 nm / RIU, AS of 18,100 RIU − 1 and maximum SR of 7.69 × 10 − 6 RIU is obtained. The maximum values of the sensor features are obtained for the analyte with RI 1.375 RIU for both configurations. Finally, a comparison between sensing parameters of plasmonic material ITO and TiO2 is performed, and optimum material is identified when used with Au for RI sensing.Keywords
This publication has 55 references indexed in Scilit:
- Spiral Photonic Crystal Fiber-Based Dual-Polarized Surface Plasmon Resonance BiosensorIEEE Sensors Journal, 2017
- Aptamer-based fiber sensor for thrombin detectionJournal of Biomedical Optics, 2016
- Highly Sensitive SPR Sensor Based on D-shaped Photonic Crystal Fiber Coated with Indium Tin Oxide at Near-Infrared WavelengthPlasmonics, 2016
- Highly Sensitive Side-Polished Birefringent PCF-Based SPR Sensor in near IRPlasmonics, 2016
- Highly sensitive multi-core flat fiber surface plasmon resonance refractive index sensorOptics Express, 2016
- Highly sensitive D shaped PCF sensor based on SPR for near IROptical and Quantum Electronics, 2016
- Theoretical analysis of surface plasmon resonance based fiber optic sensor using ITO and ZnO thin filmsOptical and Quantum Electronics, 2015
- Photonic Crystal Fiber-Based Surface Plasmon Resonance Sensor with Selective Analyte Channels and Graphene-Silver Deposited CoreSensors, 2015
- Photonic crystal fiber based surface plasmon resonance chemical sensorsSensors and Actuators B: Chemical, 2014
- SPR Biosensor Based on Polymer PCF Coated With Conducting Metal OxideIEEE Photonics Technology Letters, 2014