Combined Quantification of Liver Perfusion and Function with Dynamic Gadoxetic Acid–enhanced MR Imaging
Authors:
- Steven SourbronSSSteven Sourbron
- Wieland H. SommerWSWieland H. Sommer
- Maximilian F. ReiserMRMaximilian F. Reiser
- Christoph J. ZechCZChristoph J. Zech
- 1 June 2012
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 263 (3) , 874-883
Abstract
To evaluate the feasibility of quantifying hepatic perfusion and function by using dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging with the hepatobiliary contrast agent gadoxetic acid and a dual-inlet two-compartment uptake model. The study was approved by the local institutional review board, and written informed consent was obtained from all patients. Data were acquired between October 2008 and November 2009 in 24 patients with hepatic metastases from neuroendocrine tumors (13 men, 11 women; mean age, 59.8 years). DCE MR imaging was performed at 3.0 T with a standard dose of gadoxetic acid and a three-dimensional sequence, with 48 sections of data acquired every 2.2 seconds for 5 minutes. For each patient, a plasma flow map was calculated by means of deconvolution and the model was fitted to six region-of-interest curves. Results were evaluated with goodness-of-fit analysis and, in normal-appearing liver tissue, by comparing perfusion parameters with those reported in the literature. Interobserver effects in the selection of arterial and venous input functions were assessed. With an arterial delay parameter, the model provided a good fit to all data. Values for arterial and venous plasma flow and extracellular volume in normal-appearing liver tissue were comparable to those in the literature. The mean intracellular uptake rate is 3.4/100/min with a standard deviation of 1.9/100/min The model also provided a good fit in all tumor data, producing high arterial flow fraction (87%) and lower uptake (1.7/100/min) . Bias due to observer-dependent differences in the selection of the input functions was negligible. The analysis of dynamic gadoxetic acid-enhanced MR images with the dual-inlet two-compartment uptake model presents a new and practical approach for measuring arterial and venous perfusion and hepatic function in a single acquisition.Keywords
This publication has 21 references indexed in Scilit:
- Dynamic contrast‐enhanced MRI of neuroendocrine hepatic metastases: A feasibility study using a dual‐input two‐compartment modelMagnetic Resonance in Medicine, 2010
- Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast‐enhanced MRI alone and in combination: Preliminary experienceJournal of Magnetic Resonance Imaging, 2010
- Hepatic Metastases: In Vivo Assessment of Perfusion Parameters at Dynamic Contrast-enhanced MR Imaging with Dual-Input Two-Compartment Tracer Kinetics ModelRadiology, 2008
- Advanced Liver Fibrosis: Diagnosis with 3D Whole-Liver Perfusion MR Imaging—Initial ExperienceRadiology, 2008
- MR Imaging in Patients with Suspected Liver Metastases: Value of Liver-specific Contrast Agent Gd-EOB-DTPAMagnetic Resonance in Medical Sciences, 2007
- Enhancement of Focal Liver Lesions at Gadoxetic Acid–enhanced MR Imaging: Correlation with Histopathologic Findings and Spiral CT—Initial ObservationsRadiology, 2005
- Hepatic Flow Parameters Measured with MR Imaging and Doppler US: Correlations with Degree of Cirrhosis and Portal HypertensionRadiology, 2003
- Assessment of hepatic perfusion parameters with dynamic MRIMagnetic Resonance in Medicine, 2001
- Assessment of hepatic perfusion in pigs by pharmacokinetic analysis of dynamic MR imagesJournal of Magnetic Resonance Imaging, 1999
- Contrast agents in magnetic resonance imaging of the liver: Present and futureBiomedicine & Pharmacotherapy, 1998