Objective: This study evaluates the feasibility of direct scatter and attenuation correction of whole-body 68Ga-PSMA PET images in the image domain using deep learning. Methods: Whole-body 68Ga-PSMA PET images of 399 subjects were used to train a residual deep learning model, taking PET non–attenuation-corrected images (PET-nonAC) as input and CT-based attenuation-corrected PET images (PET-CTAC) as target (reference). Forty-six whole-body 68Ga-PSMA PET images were used as an independent validation dataset. For validation, synthetic deep learning–based attenuation-corrected PET images were assessed considering the corresponding PET-CTAC images as reference. The evaluation metrics included the mean absolute error (MAE) of the SUV, peak signal-to-noise ratio, and structural similarity index (SSIM) in the whole body, as well as in different regions of the body, namely, head and neck, chest, and abdomen and pelvis. Results: The deep learning–guided direct attenuation and scatter correction produced images of comparable visual quality to PET-CTAC images. It achieved an MAE, relative error (RE%), SSIM, and peak signal-to-noise ratio of 0.91 ± 0.29 (SUV), −2.46% ± 10.10%, 0.973 ± 0.034, and 48.171 ± 2.964, respectively, within whole-body images of the independent external validation dataset. The largest RE% was observed in the head and neck region (−5.62% ± 11.73%), although this region exhibited the highest value of SSIM metric (0.982 ± 0.024). The MAE (SUV) and RE% within the different regions of the body were less than 2.0% and 6%, respectively, indicating acceptable performance of the deep learning model. Conclusions: This work demonstrated the feasibility of direct attenuation and scatter correction of whole-body 68Ga-PSMA PET images in the image domain using deep learning with clinically tolerable errors. The technique has the potential of performing attenuation correction on stand-alone PET or PET/MRI systems.Keywords
This publication has 36 references indexed in Scilit:
- Comparison of atlas-based techniques for whole-body bone segmentationMedical Image Analysis, 2017
- Whole‐body bone segmentation from MRI for PET/MRI attenuation correction using shape‐based averagingMedical Physics, 2016
- Magnetic resonance imaging-guided attenuation correction in whole-body PET/MRI using a sorted atlas approachMedical Image Analysis, 2016
- One registration multi-atlas-based pseudo-CT generation for attenuation correction in PET/MRIEuropean Journal of Nuclear Medicine and Molecular Imaging, 2016
- Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRINeuroImage, 2016
- Vision 20/20: Magnetic resonance imaging‐guided attenuation correction in PET/MRI: Challenges, solutions, and opportunitiesMedical Physics, 2016
- Region specific optimization of continuous linear attenuation coefficients based on UTE (RESOLUTE): application to PET/MR brain imagingPhysics in Medicine & Biology, 2015
- Joint Estimation of Activity and Attenuation in Whole-Body TOF PET/MRI Using Constrained Gaussian Mixture ModelsIEEE Transactions on Medical Imaging, 2015
- Clinical Assessment of MR-Guided 3-Class and 4-Class Attenuation Correction in PET/MRMolecular Imaging and Biology, 2014
- MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based MethodsJournal of Nuclear Medicine, 2011