Implementation and validation of collapsed cone superposition for radiopharmaceutical dosimetry of photon emitters
- 25 September 2015
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (20) , 7861-7876
Abstract
Two collapsed cone (CC) superposition algorithms have been implemented for radiopharmaceutical dosimetry of photon emitters. The straight CC (SCC) superposition method uses a water energy deposition kernel (EDKw) for each electron, positron and photon components, while the primary and scatter CC (PSCC) superposition method uses different EDKw for primary and once-scattered photons. PSCC was implemented only for photons originating from the nucleus, precluding its application to positron emitters. EDKw are linearly scaled by radiological distance, taking into account tissue density heterogeneities. The implementation was tested on 100, 300 and 600 keV mono-energetic photons and 18F, 99mTc, 131I and 177Lu. The kernels were generated using the Monte Carlo codes MCNP and EGSnrc. The validation was performed on 6 phantoms representing interfaces between soft-tissues, lung and bone. The figures of merit were γ (3%, 3 mm) and γ (5%, 5 mm) criterions corresponding to the computation comparison on 80 absorbed doses (AD) points per phantom between Monte Carlo simulations and CC algorithms. PSCC gave better results than SCC for the lowest photon energy (100 keV). For the 3 isotopes computed with PSCC, the percentage of AD points satisfying the γ (5%, 5 mm) criterion was always over 99%. A still good but worse result was found with SCC, since at least 97% of AD-values verified the γ (5%, 5 mm) criterion, except a value of 57% for the 99mTc with the lung/bone interface. The CC superposition method for radiopharmaceutical dosimetry is a good alternative to Monte Carlo simulations while reducing computation complexity.Keywords
Funding Information
- Institut National de la Santé et de la Recherche Médicale (PC201227)
This publication has 12 references indexed in Scilit:
- Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT imagesPhysics in Medicine & Biology, 2013
- Study of the Impact of Tissue Density Heterogeneities on 3-Dimensional Abdominal Dosimetry: Comparison Between Dose Kernel Convolution and Direct Monte Carlo MethodsJournal of Nuclear Medicine, 2012
- Validation of a personalized dosimetric evaluation tool (Oedipe) for targeted radiotherapy based on the Monte Carlo MCNPX codePhysics in Medicine & Biology, 2006
- Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernelsPhysics in Medicine & Biology, 2005
- Voxeldose: A Computer Program for 3-D Dose Calculation in Therapeutic Nuclear MedicineCancer Biotherapy and Radiopharmaceuticals, 2003
- The collapsed cone superposition algorithm applied to scatter dose calculations in brachytherapyMedical Physics, 2000
- Point kernels and superposition methods for scatter dose calculations in brachytherapyPhysics in Medicine & Biology, 2000
- Dose calculations for external photon beams in radiotherapyPhysics in Medicine & Biology, 1999
- A Monte Carlo approach to patient-specific dosimetryMedical Physics, 1996
- Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous mediaMedical Physics, 1989