Seismic Retrofit of an Existing RC Building With Isolation Devices Applied at Base
Authors:
Open Access
- 9 July 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Built Environment
- Vol. 6
Abstract
Nowadays, seismic retrofit through isolation strategy represents a consolidated technique of protection against design earthquakes. This technique is also applied on existing structures extensively, due to the fact that it usually does not require any interruption of the building use and occupants evacuation. If applicable, it rapidly allows the seismically retrofitting of a building installed with seismic devices with low horizontal stiffness between the structure and the foundation decoupling, in fact, this allows the motion of the superstructure from the ground one. In this paper an application on an existing RC building of the seismic isolation is presented. The chosen building was built in the ‘90s only for vertical loads and realized without any detailing rule for structural ductility. The seismic retrofitting requirement stems from the fact that only recently, after the National seismic hazard maps update in 2003, the considered area has been upgraded to a medium-low seismic intensity zone, while at construction time no seismic classification was in existence by law. The case study peculiarity is that the seismic retrofitting has required an addition to seismic devices at the base, with related interventions such as the application of a bracing system consisting of two elastic steel frames. This intervention is required for stiffening the superstructure and, therefore, minimizing the higher vibration modes effects. The paper presents the main results obtained with a FEM model, implemented for simulating the initial and the design state when the interventions are considered. Finally, some results of non-linear dynamic time-history analyses are illustrated and commented for verifying superstructure elements and seismic devices.Keywords
This publication has 30 references indexed in Scilit:
- Ground Motion Record Selection Based on Broadband Spectral CompatibilityEarthquake Spectra, 2014
- REXEL: computer aided record selection for code-based seismic structural analysisBulletin of Earthquake Engineering, 2009
- Recent advances in nonlinear passive vibration isolatorsJournal of Sound and Vibration, 2008
- Nonlinear Dynamic Response of HDRB and Hybrid HDRB-Friction Sliders Base Isolation SystemsBulletin of Earthquake Engineering, 2005
- A parametric study of linear and non-linear passively damped seismic isolation systems for buildingsEngineering Structures, 2004
- Seismic Isolation Systems for Developing CountriesEarthquake Spectra, 2002
- Base isolation for retrofitting historic buildings: Evaluation of seismic performance through experimental investigationEarthquake Engineering & Structural Dynamics, 2001
- Seismic isolation of civil buildings in EuropeProgress in Structural Engineering and Materials, 1998
- Design of yielding or friction-based dissipative bracings for seismic protection of buildingsEngineering Structures, 1995
- Aseismic base isolation: review and bibliographySoil Dynamics and Earthquake Engineering, 1986