Utility of Indocyanine Green Fluorescence Imaging for Intraoperative Localization in Reoperative Parathyroid Surgery
Authors:
- 27 October 2015
- journal article
- research article
- Published by SAGE Publications in Surgical Innovation
- Vol. 26 (6) , 774-779
Abstract
Background. Due to the variations in anatomic location, the identification of parathyroid glands may be challenging. Although there have been advances in preoperative imaging modalities, there is still a need for an accurate intraoperative guidance. Indocyanine green (ICG) is a new agent that has been used for intraoperative fluorescence imaging in a number of general surgical procedures. Its utility for parathyroid localization in humans has not been reported in the literature. Results. We report 3 patients who underwent reoperative neck surgery for primary hyperparathyroidism. Using a video-assisted technique with intraoperative ICG fluorescence imaging, the parathyroid glands were recognized and removed successfully in all cases. Surrounding soft tissue structures remained nonfluorescent, and could be distinguished from the parathyroid glands. Conclusions. This report suggests a potential utility of ICG imaging in intraoperative localization of parathyroid glands in reoperative neck surgery. Future work is necessary to assess its benefit for first-time parathyroid surgery.Keywords
This publication has 13 references indexed in Scilit:
- Reoperative Parathyroid Surgery; Localization Procedures2015
- Radioguided occult lesion localization for minimally invasive parathyroidectomyNuclear Medicine Communications, 2014
- Clinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgerySurgical Endoscopy, 2014
- Surgeon and Staff Radiation Exposure During Radioguided Parathyroidectomy at a High-Volume InstitutionAnnals of Surgical Oncology, 2014
- Indocyanine Green (ICG) Fluorescent Cholangiography During Robotic CholecystectomySurgical Innovation, 2014
- A New Classification of Positive Sestamibi and Ultrasound Scans in Parathyroid LocalizationWorld Journal of Surgery, 2012
- The clinical use of indocyanine green as a near‐infrared fluorescent contrast agent for image‐guided oncologic surgeryJournal of Surgical Oncology, 2011
- Dose-response and postoperative confusion following methylene blue infusion during parathyroidectomyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2007
- Fluorescence-guided minimally invasive parathyroidectomy: a novel detection technique for parathyroid glandsSurgical Endoscopy, 2006
- Methylene Blue and Sestamibi: Complementary Tools for Localizing ParathyroidsThe Laryngoscope, 2001